97-0020-01-01
9
Planning Preparations
This
g
u
id
e for
u
se by qu
alifi
ed installers only.
Figure 4
Wiring and Breakers Block Diagram for Freedom SW 2012 / 2024
2012 and 2024
Inverter/Charger
120 V AC OUT
120 V AC IN
Battery (Bank)
12 or 24 V
4 AWG
†
150 A fuse
†††
2/0 AWG
†
275 A fuse
††
8 AWG Chassis GND*
10 AWG
10 AWG
HOT = BLACK
NEUTRAL = WHITE
GND = GREEN/Bare
HOT BUS
HOT BUS
TO AC APPLIANCE
LOADS
MAIN ELECTRICAL PANEL
FROM SHORE OR
GENERATOR POWER
OPTIONAL
GFCI duplex receptacle special kit
15 A output limit
HARDWIRE CONNECTIONS
20 A MAX in inverter
30 A MAX in pass-through
Neutral
GND
15 A
20 A
Neutral
GND
30 A
MAIN
* Recreational Vehicles only. For Marine applications see NOTE below.
NOTE: The DC grounding conductor may be one size smaller than the minimum size conductor required for the DC current carrying conductors providing the overcurrent protection device in the DC
positive conductor is rated no greater than 135% of the ampacity of the DC grounding conductor and the conductor is no smaller than 16 AWG.
††
Class T or equivalent
Freedom SW 2012
†
In free air, as per NEC Table 310.17
for 75 C rated copper conductor.
†††
Class T or equivalent
Freedom SW 2024
IMPORTANT:
Read Owner’s and In-
stallation Guides prior to installation.
Always refer to local and national
electrical codes for proper wire and
breaker sizes prior to installation.
Freedom SW 3K2K InvChg Install Guide.book Page 9 Wednesday, October 12, 2011 4:40 PM