24
Freedom XC Owner’s Guide
Basic Installation Procedures
Step 5: Connecting AC Output to an Existing AC Circuit
Do not connect the Freedom XC to an AC branch circuit that has
high-power consumption loads.
The Freedom XC will not operate electric heaters, air conditioners,
stoves, and other electrical appliances that consume more than its
rated watts.
A manufacturer-tested and approved GFCI must be connected to the
Freedom XC AC output, and GFCI protection must be provided on
every receptacle connected to the AC hard wired installation. Other
types may fail to operate properly when connected to the Freedom
XC. See “Ground Fault Circuit Interrupters (GFCIs)” on page 16.
WARNING
FIRE, SHOCK, AND ENERGY HAZARDS
Make sure wiring is disconnected from all electrical sources before
handling. All wiring must be done in accordance with local and national
electrical wiring codes.
Failure to follow these instructions can result in death or serious injury.
NOTICE
EQUIPMENT DAMAGE
Do not connect any AC source (such as a generator or utility power) to
the AC output wiring of the Freedom XC.
The Freedom XC will not operate if its output is connected to AC voltage
from another source, and potentially hazardous or damaging conditions
may occur. These conditions can occur even if the inverter is off.
Failure to follow these instructions can damage the unit and/or equipment.
Freedom XC Series INV-CHG Owners Guide.book Page 24 Wednesday, June 7, 2017 3:13 PM
Summary of Contents for 817-1050
Page 2: ...Freedom XC Series INV CHG Owners Guide book Page ii Wednesday June 7 2017 3 13 PM...
Page 12: ...Freedom XC Series INV CHG Owners Guide book Page x Wednesday June 7 2017 3 13 PM...
Page 14: ...Freedom XC Series INV CHG Owners Guide book Page ii Wednesday June 7 2017 3 13 PM...
Page 22: ...Freedom XC Series INV CHG Owners Guide book Page 8 Wednesday June 7 2017 3 13 PM...
Page 52: ...Freedom XC Series INV CHG Owners Guide book Page 38 Wednesday June 7 2017 3 13 PM...
Page 76: ...Freedom XC Series INV CHG Owners Guide book Page 62 Wednesday June 7 2017 3 13 PM...
Page 88: ...Freedom XC Series INV CHG Owners Guide book Page 74 Wednesday June 7 2017 3 13 PM...
Page 89: ...Freedom XC Series INV CHG Owners Guide book Page i Wednesday June 7 2017 3 13 PM...