44
Freedom HF Owner’s Guide
Specifications
NOTE
: These specifications refer to inverter mode.
DC Input
1000-watt models
1500 and 1800-watt models
Operating voltage range for all models including
Freedom HF 1800 T (806-1840-01 G2 TDN8853)
10.5–15.5 VDC (low limit)
11.8–15.5 VDC (high limit)
10.5–15.5 VDC (low limit)
11.8–15.5 VDC (high limit)
Operating voltage range for Freedom HF 1500
and Freedom HF 1800 T (806-1840-01, 806-
1840-03, 806-1840-04)
n/a
10.5–15.5 VDC (low limit)
11.8–15.5 VDC (mid limit)
12.1–15.5 VDC (high limit)
Safe non-operating voltage range
0–16 VDC
0–16 VDC
Nominal voltage for all models
12.5 VDC
12.5 VDC
Nominal current at full load
100 ADC
180 ADC
AC Output
1000-watt models
1500 and 1800-watt models
Output voltage
115 VAC
115 VAC
Continuous power
1.0kW @ 25 °C
1.8kW @ 25 °C
1.5kW @ 25 °C (Freedom HF 1500 only)
Surge power
17 AAC
(2kW for 200 ms)
30 AAC
(3.6kW for 300 ms)
Max short-circuit current
55 AAC peak
55 AAC peak
Frequency
60 Hz
60 Hz
Wave shape
Modified Sine Wave
Modified Sine Wave
Power derating above 40 °C ambient temp
See “Invert Power Derating vs. Ambient Temperature” on page 31.
Peak efficiency
87%
87%
Full load efficiency
80%
80%
Other
1000-watt models
1500 and 1800-watt models
No load input power (producing output voltage)
10W
10W
Off mode current draw
1mA
1mA
Freedom HF InvChg Owners Guide.book Page 44 Wednesday, September 13, 2017 6:20 PM
Summary of Contents for 806-1020
Page 2: ...Freedom HF InvChg Owners Guide book Page ii Wednesday September 13 2017 6 20 PM...
Page 12: ...Freedom HF InvChg Owners Guide book Page x Wednesday September 13 2017 6 20 PM...
Page 14: ...Freedom HF InvChg Owners Guide book Page ii Wednesday September 13 2017 6 20 PM...
Page 60: ...Freedom HF InvChg Owners Guide book Page 46 Wednesday September 13 2017 6 20 PM...
Page 61: ...Freedom HF InvChg Owners Guide book Page i Wednesday September 13 2017 6 20 PM...