background image

30A Showroom Charger

SBC1230-S

Summary of Contents for REDARC SBC1230-S

Page 1: ...30A Showroom Charger SBC1230 S ...

Page 2: ...s or lack of experience and knowledge unless they are supervised or have been instructed on how to use the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the system 2 This charger is designed for use with 12V LEAD ACID type batteries only including AGM EFB and GEL The charger should not be used for other battery types or for ch...

Page 3: ...ents 2 Specifications 3 Pack Contents 3 Dimensions 4 1 Product Function 5 1 1 Charging Process 6 1 2 Pre Charge Analysis 6 1 3 Main Charge 6 1 4 Post Charge Analysis 6 1 5 Long Term Charging 6 2 Operation 7 2 1 Setup 7 2 2 Maintenance 7 Two Year Product Warranty 10 ...

Page 4: ...0 C 40 C Storage Temperature 40 C 85 C Cooling Method Convection Compliance Protection Class I EMC Emission Class A Climate Class B Degree of Ingress Protection Horizontal position IP40 Vertical position IP44 Standards EN 60335 1 EN 60335 2 29 EN 61000 6 2 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 11 EN 61000 6 4 Class A General Specifications Dimensions L x W x H...

Page 5: ...4 DIMENSIONS 227mm 125mm 62mm 230V Power Cable Connection 12V Battery Cable Connection 5 Metre 230V Power Cable 2 5 Metre 12V Battery Cable ...

Page 6: ...rrent A over time t The charging process includes Step 1 Pre charge analysis Step 2 Main charge Step 3 Maximum charge Step 4 Battery error detection Step 5 Float charge Step 6 Sleep Step 7 Wake up 30A 14 4V U V I A 1 2 3 4 5 6 7 13 6V 0 8A 0A Figure 1 During this process charge status of the battery is shown by the LED display shown in Figure 2 Warning Triangle LED Battery Level Indicator Power Bu...

Page 7: ...ing charging battery charge is shown by the number of LEDs illuminated The blinking segment above these LEDs indicates active charging Once full battery charge is reached all 5 LED segments remain illuminated If the measured battery voltage is below 2 0V the charger will enter Error Mode and the Warning Triangle above the Battery Level Indicator will begin to flash 1 4 Post Charge Analysis The Sho...

Page 8: ... the vicinity of a Lead Acid battery is dangerous Batteries generate explosive gases during normal operation Disconnect mains supply before making or breaking connections to the battery Do not connect cables in reverse polarity e g RED clamp to B and BLACK clamp to B even though the charge output is protected against shortcircuting and wrong connections To make sure the correct charging voltages a...

Page 9: ... Figure 3 Software If the charger requires a software update it can be done through the micro USB port at the end of the charger seen in Figure 4 Necessary information will be given along with the software Figure 4 ...

Page 10: ...9 NOTES ...

Page 11: ... control of Redarc 7 Warranty claims in respect of a Product must be made in writing to Redarc at the postal address or email address specified in clause 21 within the Warranty Period Such claims must include the following 7 1 details of the alleged defect or fault and the circumstances surrounding the defect or fault 7 2 evidence of the claim including photographs of the Product where the subject...

Page 12: ... Canada 1 604 260 5512 Mexico 52 558 526 2898 UK Europe power redarcelectronics eu www redarcelectronics eu 44 0 20 3930 8109 Free technical assistance For product and technical support contact your regional distributor call our head office between 8 00am to 5 30pm Australian Central Standard Time Monday to Friday or send an email using the regional specific details outlined below Copyright 2019 R...