975-0390-01-01
9
Freedom Inverter/Charger Configuration
Setting Battery Types on the Main Unit
You can attach different types of lead-acid batteries to the Freedom
HF. Before installing batteries make sure that you configure the unit
to optimize the charging process.
The settings can be changed by adjusting the dip switches found on
the main unit behind the display panel.
To adjust the battery type setting:
By default the battery type is set to Flooded (OFF|ON) for all
models except Freedom HF 1800 T (806-1840-03) which is set to
AGM (ON|ON).
1. Detach the Display Panel to expose the Dip Switches.
2. Use the tip of your fingernail or a small screw driver with a flat
tip to adjust the switches.
Battery
Type
Dip Switch
Setting
Switch 1|Switch 2
Bulk/
Absorption
Float
Fixed
OFF|OFF
13.5
13.5
Flooded
OFF|ON (default)
14.4
13.5
GEL
ON|OFF
14.2
13.8
AGM
ON|ON
14.3
13.4
Figure 2
Dip Switches (Default Settings Shown)
ON
OFF
Switch 1 | Switch 2
Freedom HF InvChg Owners Guide.book Page 9 Wednesday, September 13, 2017 6:20 PM