5.  Connect Power using a 12VDC Power Supply (Xantech Model 781RG or 782-00). 

 

 

Figure 2: Connecting to the MRC88 Controller 

 

E

NABLING THE 

RS2321X8 R

OUTER

(Drag450MRC Version 3.0.build 77 or higher) 

Note: 

Refer to 

Figure 3 

for Software Configuration. 

1.  Start DragMRC Software and open a new or existing MRC88 project. 
2.  Click on the RS232 Settings Tab. 
3.  Click on the 

Use Router

 

check box under the 

Com Port

 or 

Expansion Port

 RS232 Sections. 

 

You can now configure each of the 8 ports of the router individually to communicate with 8 different Serial devices. 
 

C

ONFIGURING 

P

ORT 

S

ETTINGS

1. 

Selecting Router Port: 

Click on 

 

drop-down menu and select the Router Port to configure. 

2. 

Configuring Port: 

Click on the drop-down menus for 

Baud Rate, Data Bits, Parity, 

and

 Stop Bit 

and set to 

Manufactures specification for the Serial Device connected to the selected Router Port. 

Note: 

Please refer to the 

devices manual for the proper Port Configurations or consult directly with the Manufacturer. 

1. 

Process RS232 Input: 

Click on this check box 

 

for bi-directional devices or any device that will 

return strings to the MRC88’s Serial Port. 

Note: 

If this port is not selected, the MRC88 will ignore any commands 

being sent back from the external device.  

2.  Repeat this process for all Router Ports being used. 
3. 

Default Port Selection:

 If there is a 

main

 RS232 Serial Device that might randomly send strings back to the 

MRC88 (Xantech XDT Dual Tuner, Lighting or Temperature Controller etc…) you can select the port on the router 
this device is connected to and the Router will automatically always return to this port after any selection is made 
to another output port. 

 

 

 

© 2005 Xantech Corporation 

Summary of Contents for RS2321X8

Page 1: ...een the 8 ports when used with the MRC88 MRAudio8x8 and SmartPad LCD control products Each port when selected allows for bi directional serial communication for local and remotely located serial devic...

Page 2: ...s OUTPUT SERIAL WIRING Serial RS422 Output Wiring Ports 1 thru 4 Note Use Xantech Model RS422232 RS422 to RS232 Converter Module to convert the RS422 output back to standard RS232 Serial configuration...

Page 3: ...ol capabilities from 2 Serial Ports to up to 16 Serial Ports Note Refer to Figure 2 MRC88 Integration CONNECTING TO THE MRC88 1 Connect the Male end of a standard DB9 Serial cable pinned 1 1 to the MR...

Page 4: ...Baud Rate Data Bits Parity and Stop Bit and set to Manufactures specification for the Serial Device connected to the selected Router Port Note Please refer to the devices manual for the proper Port Co...

Page 5: ...e room light OFF via a Lighting Control system on Port 4 1 Right Click on the RS232 Command to be routed in the Macro Command List window 2 Select RS232 Port from the Drop Down Menu 3 Select the Port...

Page 6: ...oftware Configuration 1 Start Dragon Drop IR SPLCD Software and open a new or existing project 2 Click on the OPTIONS Tab 3 Click on the RS232 Settings Button 4 Click on the Enable Router check box Yo...

Page 7: ...l automatically always return to this port after the last command is sent PROGRAMMING THE SMARTPAD LCD ROUTING THE RS232 STRINGS Once the RS2321X8 Router is configured you may now place commands onto...

Page 8: ...on position located under the Configuration Setup Access Panel See Figure 7 2 Confirm the RC68 Group Code dials are set to the desired Group Code setting located in under the Configuration Setup Acces...

Page 9: ...ONG PREV SONG FF REW etc 4 Program the PM110 Source Buttons with the RS2321X8 Router RC68 Commands a In Dragon Drop IR Software click on the PALETTE Menu and click on Select RC68 Command Palette from...

Page 10: ...single lighting system via it s Serial Port 1 Configure the RS2321X8 Router for Stand Alone Operation as outlined above 2 Connect all devices as shown in Figure 9 below 3 Create a 2 command Macro und...

Page 11: ...r RT8 RT16 10 should be chosen by default e Change the CODE GROUP to 90 as shown in Figure 7 above Overlay should be selected to C f Click on the proper Router button as shown on the RC68 Button 1 2 3...

Page 12: ...Page 12 RS2321X8 Serial Router Fig 10 SmartPad LCD Dragon Programming for Example 2 2005 Xantech Corporation...

Page 13: ...Standalone operation IR control RS2321X8 behaves as standard switch Meaning the signal placed on the pins will be a 1 1 pin configuration between INPUT and OUTPUT Tx and Rx only need to be specific Pi...

Page 14: ...e Data 4 5 6 Receive Data 7 8 BAUD RATE SELECTOR SWITCH Position Selection 0 300 baud 1 600 baud 2 1200 baud 3 2400 baud 4 4800 baud 5 9600 baud 6 19200 baud 7 38400 baud 8 56000 baud B Unused C Unuse...

Page 15: ...RS2321X8 Serial Router Page 15 NOTES 2005 Xantech Corporation...

Page 16: ...Page 16 RS2321X8 Serial Router XANTECH CORPORATION 13100 Telfair Avenue Sylmar CA 91342 3829 phone 818 362 0353 fax 818 362 9506 Part No 08901020 Rev A 04 07 05 2005 Xantech Corporation...

Reviews: