GENERAL INFORMATION 

To enhance the ease of installation and obtain optimum performance from the PA4100X, we recommend that you first 
become familiar with all its features and special capabilities by studying the descriptions and instructions in this 
manual.  

The PA4100X was designed to meet the audio power amplifier needs of custom installed multi-zoned systems with 
high sonic quality and hi power output.  It is a 4 Channel amplifier that is primarily intended to interface with the 
MRC88 

W

hole-house 

A

udio 

V

ideo 

E

ntertainment System for Zones 7 and 8 Preamp outputs or for Sub-Zone 

amplification of zones 1-6. It may also be used as a standalone 2-zone amplifier. Specific features and technology are 
as follows: 

Figure 1: The Model PA4100X Amplifier 

Cost/Size Efficiency

.  The PA4100X features four 100-watt power amplifiers.  This permits each PA4100X to drive 2-

zones in a multi-zone system -- each with a 100-watt stereo amplifier per zone. 

Remote ON/OFF Control Jacks (C1 & C2)

.  These 3.5mm Stereo Mini Jacks allow the PA4100X to be powered on 

and off and muted by a positive DC voltage ranging between 5 and 30 volts (11mA @ 12 V).  Specifically, when 
interfaced with the Control Out jacks of zones 7 & 8 on the MRC88 (labeled CO1 and CO2), it permits the MRC88 to 
power the PA4100X ON and OFF automatically with zone ON/OFF commands or any 12VDC control signal.  

Input Level Flexibility

. The input level (sensitivity range) is individually adjustable (per stereo pair) from a low of 0.2 

volts up to 3 volts.  This gives the installer the ability to adjust the overall gain of the system or zone.  For instance, 
there may be a need to adjust the amplifier to deliver a controlled, maximum sound level into a zone when the volume 
control on the preamp is set to maximum.  This would act as a volume limiter for any particular zone (i.e. to prevent 
the kids from over-driving wall speakers, etc.).  

Low Impedance Capability

.  Each amplifier is 4-Ohm safe under music conditions. This means, for instance, that 

you can drive two pairs of 8-Ohm speakers in stereo mode in each zone with ease. 

Peak/Clip LED Indication: 

 Whenever either amplifier channel output starts to enter a clipping state, the channels 

front panel LED will illuminate RED. After the amp stops clipping the LED will return to its normal state 5-6 seconds 
after clipping stops. 

Summary of Contents for PA4100X

Page 1: ...TING EQUIPMENT 2 GENERAL INFORMATION 3 PA4100X PANEL AND FEATURE DESCRIPTIONS 5 INSTALLATION PHYSICAL LOCATION AND MOUNTING 8 CONNECTING THE PA4100X 9 Stereo Mode Connections 9 Speaker Phasing 10 Conn...

Page 2: ...hould be mounted to a wall or ceiling only as recommended by the manufacturer 8 Ventilation The appliance should be situated so that its location or position does not interfere with its proper ventila...

Page 3: ...powered on and off and muted by a positive DC voltage ranging between 5 and 30 volts 11mA 12 V Specifically when interfaced with the Control Out jacks of zones 7 8 on the MRC88 labeled CO1 and CO2 it...

Page 4: ...ction Circuit This feature protects the PA4100X if a short or very low impedance is detected at the speaker terminals with each amplifier pair protected separately Normal operation is restored automat...

Page 5: ...hannels of PA4100X may be controlled remotely from the MRC88 via the CI1 and CI2 Control Inputs or any Voltage Control Signal When both channels enter STANDBY Mode the front LEDS will turn off leaving...

Page 6: ...put LEVEL Control This screwdriver adjustable control for each stereo pair allows the input level for full rated power output to be adjusted over a range of 0 2 volts to 3 volts 24 3 dB range Normally...

Page 7: ...a 3 conductor power line cord Depending on the application plug the line cord into a switched or un switched 120V 60 Hz AC outlet or 240 VAC 50 Hz on the 240 V version 13 Rear Panel POWER LED This LE...

Page 8: ...ver for adequate cooling 2 If mounted in an equipment cabinet or other confining location allow at least 2 inches of space above the top cover see Fig 4 Be sure there are large openings in the shelf b...

Page 9: ...NG THE PA4100X LEFT RIGHT SPEAKER LEFT RIGHT A DO NOT BRIDGE 1V 2V 3V LEVEL 7 STATUS ZONE IR K E Y P A D PREAMP OUT RCA Type Patch Cords CI 1 PA435X Rear Panel Be sure speakers are connected with corr...

Page 10: ...red dot b If you are unsure of the markings you can verify the phasing Using a mono sound source such as AM radio alternately reverse the leads to one of the speakers Pick the connection that delivers...

Page 11: ...T RIGHT SPEAKER LEFT RIGHT B DO NOT BRIDGE 1V 2V 3V LEVEL CI 2 8 STATUS ZONE IR K E Y P A D PREAMP OUT 7 STATUS ZONE IR K E Y P A D PREAMP OUT REMOTE AMP CO1 VIDEO OUT 8 VIDEO OUT 7 REMOTE AMP CO1 MRC...

Page 12: ...PA4100X 3 Using two 3 5mm Stereo Mini Plug cables connect the Remote Amp CO1 jack on the rear of the MRC88 to the CI1 jack on the rear of the PA4100X 4 Similar to step 3 connect the Remote Amp CO2 ja...

Page 13: ...and out every 3 to 5 seconds Speaker load impedance is less than 4 Ohms for Stereo mode or less than 8 Ohms for Bridged mode Make changes in speakers as necessary to obtain higher impedance PA4100X d...

Page 14: ...55 kHz Input Sensitivity at rated power stereo mode input gain Max 0 2 V Default 1 0 V Minimum 3V Input Impedance Local Inputs 22 kOhms Common Audio Buss Inputs 70kOhms Power Source 120 VAC 60 Hz TMR...

Page 15: ...Model PA4100X Page 15 2003 Xantech Corporation...

Page 16: ...Page 16 Model PA4100X 2003 Xantech Corporation XANTECH CORPORATION 12950 Bradley Avenue Sylmar CA 91342 3829 phone 818 362 0353 fax 818 362 9506 www xantech com Part No 08901195 Rev B 04 03 2003...

Reviews: