3.  The PA4100X is 4-Ohm safe in Stereo Mode.  Make sure the impedance presented to the speaker terminals by 

the speakers (or any combination of speakers) is 4-Ohms minimum.  

5.   Be sure to observe correct polarity by connecting the "+" and "–" terminal from each channel on the PA4100X to 

the corresponding "+" and "–" terminals on each speaker.  This will ensure correct "phasing" - see Fig. 5 and 
Speaker Phasing below. Since the connectors are removable, you may unplug them for ease of lead assembly. 

6.  As a rule of thumb, use 18 gauge speaker wire for speaker runs up to 30' (9m), 16 gauge up to 70' (21m), and 14 

gauge up to 150' (39m). The 4-terminal connectors accept wire sizes up to 12-gauge max. 

7.  Strip the insulation back about 1/4" (6mm) and twist the strands on each lead to prevent fraying. 

CAUTION:

  After lead ends are inserted and the screws tightened down, be sure there are no free strands that 

could cause shorting! 

Speaker Phasing 

To obtain stable imaging and full bass response, it is imperative that stereo speakers be connected "in phase" with 
each other.  You can verify this as follows: 

a)  If the "+" (positive) and "–" (negative) terminals on your speakers are correctly marked, and visible, and you have 

wired the system as shown in Figs. 5, then the system will be "in phase".  No further action is required. Most 
manufacturers identify the positive terminal with a red binding post, a "+" sign, or a red dot. 

b)  If you are unsure of the markings, you can verify the phasing. Using a mono sound source, such as AM radio, 

alternately reverse the leads to one of the speakers.  Pick the connection that delivers a solid center image 
between the speakers as well as best bass response. 

Connecting the REMOTE MASTER ON/OFF MUTE CONTROL 

As mentioned under "PA4100X PANEL AND FEATURE DESCRIPTIONS", the REMOTE MASTER ON/OFF 
CONTROL inputs (CI1 & CI2) will allow the power to the PA4100X to be turned ON, OFF, and MUTED by remotely 
applied DC Voltages.  Fig. 7 illustrates how a PA4100X can be switched ON and OFF via the MRC88 Zone 7 & 8 
Control Outputs (CO1 and CO2) or other control source.  

NOTE: To enable this feature, be sure the CI Switch (Item #14) is in the ON (UP) position.

On/Off Standby Control: 

Whenever a 5 to 30v dc voltage is applied to the TIP of the 3.5mm Stereo jack, the associated Amplifier channel will
be activated (Powered ON). When the signal applied to the TIP approaches GND, it will put the associated Amplifier 
channel in STANDBY Mode. If both Amplifier channels are in STANDBY MODE the Amplifier will enter a “low power” 
STANDBY mode (Illuminated LOGO will remain ON). 

Mute Control: 

Whenever a 5 to 30v dc voltage is applied to the RING of the 3.5mm Stereo jack, the associated Amplifier channels 
signal output will be MUTED. When the signal applied to the RING approaches GND it will UN-MUTE the associated 
Amplifier channel and the audio signal will be returned to its previous level. 

Tip:12vDC = AMP ON

Ring:12v DC = AMP MUTED

Sleeve=GND

Insulators

3.5mm Mini Plug

(3-Conductor)

Figure 6: CI Control Jack Pin Out Config 

Summary of Contents for PA4100X

Page 1: ...TING EQUIPMENT 2 GENERAL INFORMATION 3 PA4100X PANEL AND FEATURE DESCRIPTIONS 5 INSTALLATION PHYSICAL LOCATION AND MOUNTING 8 CONNECTING THE PA4100X 9 Stereo Mode Connections 9 Speaker Phasing 10 Conn...

Page 2: ...hould be mounted to a wall or ceiling only as recommended by the manufacturer 8 Ventilation The appliance should be situated so that its location or position does not interfere with its proper ventila...

Page 3: ...powered on and off and muted by a positive DC voltage ranging between 5 and 30 volts 11mA 12 V Specifically when interfaced with the Control Out jacks of zones 7 8 on the MRC88 labeled CO1 and CO2 it...

Page 4: ...ction Circuit This feature protects the PA4100X if a short or very low impedance is detected at the speaker terminals with each amplifier pair protected separately Normal operation is restored automat...

Page 5: ...hannels of PA4100X may be controlled remotely from the MRC88 via the CI1 and CI2 Control Inputs or any Voltage Control Signal When both channels enter STANDBY Mode the front LEDS will turn off leaving...

Page 6: ...put LEVEL Control This screwdriver adjustable control for each stereo pair allows the input level for full rated power output to be adjusted over a range of 0 2 volts to 3 volts 24 3 dB range Normally...

Page 7: ...a 3 conductor power line cord Depending on the application plug the line cord into a switched or un switched 120V 60 Hz AC outlet or 240 VAC 50 Hz on the 240 V version 13 Rear Panel POWER LED This LE...

Page 8: ...ver for adequate cooling 2 If mounted in an equipment cabinet or other confining location allow at least 2 inches of space above the top cover see Fig 4 Be sure there are large openings in the shelf b...

Page 9: ...NG THE PA4100X LEFT RIGHT SPEAKER LEFT RIGHT A DO NOT BRIDGE 1V 2V 3V LEVEL 7 STATUS ZONE IR K E Y P A D PREAMP OUT RCA Type Patch Cords CI 1 PA435X Rear Panel Be sure speakers are connected with corr...

Page 10: ...red dot b If you are unsure of the markings you can verify the phasing Using a mono sound source such as AM radio alternately reverse the leads to one of the speakers Pick the connection that delivers...

Page 11: ...T RIGHT SPEAKER LEFT RIGHT B DO NOT BRIDGE 1V 2V 3V LEVEL CI 2 8 STATUS ZONE IR K E Y P A D PREAMP OUT 7 STATUS ZONE IR K E Y P A D PREAMP OUT REMOTE AMP CO1 VIDEO OUT 8 VIDEO OUT 7 REMOTE AMP CO1 MRC...

Page 12: ...PA4100X 3 Using two 3 5mm Stereo Mini Plug cables connect the Remote Amp CO1 jack on the rear of the MRC88 to the CI1 jack on the rear of the PA4100X 4 Similar to step 3 connect the Remote Amp CO2 ja...

Page 13: ...and out every 3 to 5 seconds Speaker load impedance is less than 4 Ohms for Stereo mode or less than 8 Ohms for Bridged mode Make changes in speakers as necessary to obtain higher impedance PA4100X d...

Page 14: ...55 kHz Input Sensitivity at rated power stereo mode input gain Max 0 2 V Default 1 0 V Minimum 3V Input Impedance Local Inputs 22 kOhms Common Audio Buss Inputs 70kOhms Power Source 120 VAC 60 Hz TMR...

Page 15: ...Model PA4100X Page 15 2003 Xantech Corporation...

Page 16: ...Page 16 Model PA4100X 2003 Xantech Corporation XANTECH CORPORATION 12950 Bradley Avenue Sylmar CA 91342 3829 phone 818 362 0353 fax 818 362 9506 www xantech com Part No 08901195 Rev B 04 03 2003...

Reviews: