background image

Rev. 1.0.4

Item no. UM-PLM-DLC-ADD

 

Dolby

®

 Lake

®

 Controller User Manual PLM

 Edition Addendum

PLM Series

 

Powered Loudspeaker Management

 systems

Summary of Contents for PLM Series PLM 10000Q

Page 1: ...Rev 1 0 4 Item no UM PLM DLC ADD Dolby Lake Controller User Manual PLM Edition Addendum PLM Series Powered Loudspeaker Management systems...

Page 2: ...5 2 2 Mute 11 5 2 3 Phase Reverse 11 5 2 4 Meters 11 5 2 5 Speaker data block 11 5 2 6 Amplifier data block 11 5 2 7 Mute and polarity enable 12 5 3 Control Tab 13 5 3 1 Power Control 13 5 3 2 Amplifi...

Page 3: ...al Control Tab 21 5 7 1 Global Power Control 21 5 7 2 Global Temperature 21 5 7 3 Global LoadSmart 21 5 8 Global Events Tab 22 5 8 1 Log Entities 22 5 8 2 Sorting options 23 5 8 3 Filtering options 23...

Page 4: ...ts as appropriate Note that the DLC PLM Edition software has all necessary functionality to control standalone Dolby Lake Processors and Dolby Lake legacy processors as well as PLM Series units The DL...

Page 5: ...lace it in service We do however highly recommend reading through all manuals in their entirety As you become thoroughly familiar with all aspects of the PLM Series you may learn about features and op...

Page 6: ...ve instructions on Configuring your Tablet PC for working with the Dolby Lake Controller PLM Edition software Installing the Dolby Lake Controller PLM Edition application on your Tablet PC Setting up...

Page 7: ...en Installations In some situations the user may wish to have some of the same presets available in both versions To copy preset files from the existing old installation into the new DLC PLM Edition i...

Page 8: ...n the Dolby Lake Controller PLM Edition software as well as via the PLM s front panel These include for example gain adjustment monitoring of output levels and temperatures and power control Basic per...

Page 9: ...the Module icons selecting the Levels tab then tapping on the Lab gruppen info button An alternative method is from Main page button bar menu Tap the Modules button select a Module and then tap the I...

Page 10: ...ut channel then this is displayed accordingly e g low low mid high ThePLM smetersarereproducedasverticalbargraphs Each channel strip provides an attenuation fader phase reverse button and mute button...

Page 11: ...urrent meter Clip behavior is shown by a red light using a fast update rate to correctly indicate ballistics Two numerical displays are above the meter block The top display switches mode dynamically...

Page 12: ...it and the channel number The frame name is assigned in Modules Label Lock Label Frame This name also displays in Frame block line 2 on the PLM front panel display The channel number corresponds to th...

Page 13: ...ew See section 5 7 5 3 2 Amplifier Gain The Module Control tab displays a table showing the values currently set for Amplifier Gain The first row of the table shows the current Amplifier Gain settings...

Page 14: ...erates a test signal which is applied to the power output stage Measurements are taken at the power output stage and the results computed for the speaker type using data from the LoadLibrary The Load...

Page 15: ...d to initiate the LoadSmart verification Tap Yes to the confirmation button and all PLM power output channels assigned to the currently selected Module will have their loads checked The channels are m...

Page 16: ...ute state No Model Fingerprint data is missing from the Module file selected Aborted A power output channel was in a protective state during the load verification process e g temperature fault The All...

Page 17: ...malous results possibly as a result of production spreads or incorrect entry of cable data at the LoadSmart stage In such cases a starting temperature for SpeakerSafe monitoring may be entered manuall...

Page 18: ...rameter to be displayed is selected by tapping on one of the buttons in the Select curve box below the graph The options are CombinedHeadroom Thiscurveisconstructed from all the individual parameters...

Page 19: ...h parameter within the two minute sample period If Average is selected the curves will be of points representing the average of the values measured during the sample period 5 5 3 Channels The graph ca...

Page 20: ...yed in the Global Events tab However here events are filtered to show only those relevant to the currently selected Module power output channels assigned to that Module and the Frame s incorporating t...

Page 21: ...ly 5 7 2 Global Temperature The current ambient temperature the temperature of the air surrounding the cabinets may be entered on this tab Tapping on the blue button in the Ambient Temperature box ope...

Page 22: ...available for displaying a user definable subset of the log Note that the data for the most recent event is repeated in the separate horizontal pane at the bottom of the table 5 8 1 Log Entities Seven...

Page 23: ...all Modules on all frames on the system However it is possible to reduce the number of log entries to user definable subset with the filter options available on the right hand side of the table Note t...

Page 24: ...trademarks of Lab gruppen AB PLM Powered Loudspeaker Management R SMPS LoadLibrary LoadSmart SpeakerSafe and ISVPL are trademarks of Lab gruppen AB Dolby Lake and the double D symbol are registered t...

Page 25: ...L a b g r u p p e n AB S w e d e n i n t e r n a t i o n a L c o n t a c t i n f o L a b g r u p p e n c o m U S CONTACT i n f o u s t c e l e c t r o n i c c o m w w w l a b g r u p p e n c o m...

Reviews: