background image

Model MRC88 / MRAUDIO8x8 

 

Page: 23 

 

© 2005 Xantech Corporation 

e.  Slide the left or right side of the back-bar into the wall as shown in 

Figure 8

f.  Center the mounting bracket in the wall and tighten the screws until the bracket is firmly held in the wall. 

Over tightening will distort the bracket and prevent the Keypad from snapping tight against the wall. 
Under tightening will cause the Keypad to be loose against the wall. 

g.  If there is not enough room to slide the keypad in as described above, you can hold the back-bar in 

place as you run the screws through the mounting plate and into the back-bar. TIE A LONG STRING 
TO THE BACK-BAR so that you can easily retrieve it in case you drop the back-bar into the wall! 

 

MRCBOX

MRC88 Keypad Mounting Bracket

 

 

Figure 8B: Optional Keypad Back-Box for pre-install applications 

 

2-1. MRCBOX (Back-Box) Installation (optional) 

a.  Position Back-Box so inner rectangle is in a horizontal position. as shown in 

Figure 8B 

b.  Affix MRCBOX to Wall Stud at desired height with front of box flush with front of stud (or set back 

slightly) as to not interfere with Sheetrock.

 

c.  Attach ground wire to ground lug as described in Step 2a as shown above.

 

d.  Orient the Mounting Bracket so the ground lug is on the top portion of the bracket and using two 1.5” 

(38.1mm) self-tapping drywall screws (or sheet metal screws), mount the bracket to the Back Box. For 
extra rigidity use two 2” (50.8mm) self-tapping drywall screws (or sheet metal screws) through the 
bottom two screw holes.

 

3.  With the Controller/Amplifier turned off, connect the CAT5 cable to the appropriate RJ45 connector, using 

Figure 10

 as a guide for CAT5 termination. 

4.  Add or remove jumpers on the rear of the MRC88 keypad-according to Table 1 (Keypad connections). 
5.  Firmly snap the MRC88 Keypad into the bracket that you have just installed (see 

Figure 6

). 

6.  Confirm all Keypad operations. 
 

MRC88 KEYPAD REMOVAL 

 

Summary of Contents for MRC88

Page 1: ...components and the MRC88 system A Programmable Learning Remote such as the Xantech URC2 is recommended for integrating the IR commands of the MRC88 and source components into a single controller Comp...

Page 2: ...ressed Pressing of the Source Button will reverse the source icon on the LCD Display and sends IR commands programmed to the button if any to the corresponding source and common emitter outputs as wel...

Page 3: ...20 IR Sensitivity Adjustment Carefully adjust for background light level to prevent false triggering of the IR circuits Slowly turn counter clockwise to reduce sensitivity 21 LCD Backlight Adjustment...

Page 4: ...Inputs 1 Audio Video RCA Harness Capable of Audio Left Right and Video 1 Pair of speakers with Speaker Cable properly terminated into a 4 conductor WECO Plug Will be used to test Speaker outputs 1 TV...

Page 5: ...ypad is transmitted along the CAT5 cable Incorrect wiring on this cable can destroy the MRC Keypad Please test the cable connections using a proper CAT5 cable tester or using a Multimeter to check Pin...

Page 6: ...RC88 is designed for mounting on flat horizontal surfaces When mounting into a 19 rack use a proper rack shelf or drawer i e Middle Atlantic or equivalent 8 Do not remove chassis feet They are necessa...

Page 7: ...ine of the template being sure that your cut is on the outline Any cut outside of the outline by more than may not be covered by the MRC88 Keypad 1 2 Figure 8 Installing the MRC88 Keypad mounting brac...

Page 8: ...nstallation optional a Position Back Box so inner rectangle is in a horizontal position as shown in Figure 8B b Affix MRCBOX to Wall Stud at desired height with front of box flush with front of stud o...

Page 9: ...or a typical MRC88 system layout and interconnections SOURCE RELATED CONNECTIONS The following relates to all source related connections to the MRC88 Controller Unit A V In Out IR Control Sense Inputs...

Page 10: ...CONNECTIONS BASIC ADVANCED The sense input connection will typically be used to sense the power state of a source component using the Xantech CSM1 Current Sense Module optional Plug the 3 5mm mini plu...

Page 11: ...6 Since the connectors are removable you may unplug them for ease of lead assembly 4 As a rule of thumb use 18 gauge speaker wire for speaker runs up to 30 9m 16 gauge up to 70 21m and 14 gauge up to...

Page 12: ...iring on this cable can destroy the MRC Keypad Be sure to test cable for proper connections before making connections VIDEO CONNECTIONS MRC88 ONLY BASIC ADVANCED EXPANDED Composite Video 1 When runnin...

Page 13: ...cables connect the Preamp Out Left L and Right R connectors Figure 3 25 to the desired external amplifiers Audio Left and Right Input connectors CO1 AND CO2 ZONES 7 8 BASIC ADVANCED EXPANDED Zones 7 a...

Page 14: ...Address jumpers on the rear of the keypad Figure 5 17 according to Table 1 below Keypad Address Setting Application JP1 JP2 First or Single Keypad in Zone Primary Keypad connected directly to MRC88 C...

Page 15: ...greater than 8 Zones two MRC88 Controller Amplifiers can be linked together for systems up to 16 Zones Zone expansion is only available in Advanced programming configurations LINKING TWO MRC88 CONTRO...

Page 16: ...STOP PAUSE FF REW VOL VOL MUTE POWER CH CH STATUS SELECT PLAY STOP PAUSE FF REW VOL VOL MUTE D 250 feet max 76 m MRC44 Connecting Block PWR V G S IR RCVR 780 80 CFL DIRECT SUNLIGHT FRIENDLY IR RECEIV...

Page 17: ...SIC ADVANCED EXPANDED SPEAKER PHASING TO OBTAIN STABLE IMAGING AND FULL BASS RESPONSE IT IS IMPERATIVE THAT STEREO SPEAKERS BE CONNECTED IN PHASE WITH EACH OTHER YOU CAN VERIFY THIS AS FOLLOWS 1 If th...

Reviews: