background image

 

12 

 

Symptom 6: Emitters function but some (or all) components do not 
respond. 

   Cause: 

Solution 

1.  Emitter placement is incorrect. 

Reposition the Emitter so that it is directly 
over the components sensor window. 
Consult the components owners’ manual of 
the unit for the exact location of the IR 
Sensor Window. 

2. 

Emitter placement is correct 
but the signal is overpowering 
the unit or there is bleed-
through from other emitters 
close by. 

Reposition the Emitter to a position that is 
suitable for the unit. Use a 283 or 286D Blink 
style emitter (they have a lower output than 
non-blink emitters 282 and 284M). If the 
components do not need to be controlled 
directly without an IR Repeater system 
(components are located in an equipment 
closet), place a Mouse Emitter Shield cover 
over the Emitter (PN#MS1). The rounded 
(non-stick) side of the emitter is a hi-output 
side and can reflect off other devices and 
overpower some components IR Sensors. If 
using a CB12 connecting block, try a 789-44 
connecting block. This has a series resistor 
at the output, which will limit current to the 
Emitter. 

 

13 

 

Symptom #7: Absolutely No Functionality (How to determine which 
component is at fault) 

 

Component to Test  Instructions 

1.  Verify Power Supply 

With a Multimeter, measure the DC Voltage of the 
supply while it is connected to the Connecting Block. 
Put the Negative lead of the meter on the terminal 
marked GND and the Positive Lead on the terminal 
marked 12VDC (or V). You should get a reading 
between 11.5VDC and 13.0VDC. If not, remove the 
supply from the Connecting block and measure again 
this time directly on the 2.5mm Coaxial plug. If it 
reads between 11.5VDC and 13VDC, power supply is 
most likely good. Reconnect to the Connecting Block 
and proceed to step 2. NOTE: In most cases this 
will indicate the supply is good but in some cases 
the supply can still be bad (i.e. reads good when 
not plugged in but may not be able to handle the 
current load of the system.)
 

2. 

Verify Emitter. (283D 
or 286D Blink Style 
ONLY) 

Remove the power supply from the connecting block 
and all Emitters from the output. Place a jumper wire 
on the connecting block between IR and +12v. 
Reconnect the Power Supply and one emitter. The 
Emitter should Light bright and solid. Repeat for all 
emitters. 

3. 

Verify Emitter. (282M 
or 284M NON Blink 
Style) 

Use a diode tester to verify proper Emitter operation. 
Remove Emitter from Connecting Block. Place the 
Positive Lead of the tester on the TIP of the Mono 
Mini Plug and the Negative Lead on the Shield of the 
Mono Mini Plug. Meter should read a voltage. When 
the leads are reversed (Positive lead on Shield and 
Negative lead on TIP) you should not get any voltage 
reading at all. 

4.  Verify IR Receiver. 

Remove the power supply from the connecting block 
and all Emitters from the output. Place a jumper wire 
on the connecting block between IR Signal and GND. 
Reconnect the Power Supply. With a known good 
hand-held remote, shoot a constant IR Command at 
the receiver and verify the TB LED on the Receiver 
lights.  

Summary of Contents for ML85K

Page 1: ...eter hole 2 inches deep 50mm Quick Connect 3 5mm Stereo Mini Plug on 7ft cable for direct plug in to Xantech Connecting Blocks Works in normal 3 wire mode 12VDC IR GND Green Talkback LED for System Ve...

Page 2: ...not long enough Simply cut off the mini plug strip the leads and splice them to a 3 conductor extension cable with a terminal block or other means Then connect the extension cable to the 3 or 4 termin...

Page 3: ...IR Photodiode Talkback LED 791 44 Amplified Connecting Block 12 VDC GN D EMITTERS 12 VDC HIGH IR OUT ST ATUS I R IN IR RCVR 791 44 AMPLIFIE D CONNECTING BLOCK 781ERGPS Emitter 5 1 Micro Link ML IR Re...

Page 4: ...let STEP 2 Connect the 3 5mm stereo mini plug from the 481D IR Receiver ITEM A to the IR RCVR input located on the 789 44 Connecting Block ITEM B The RED connector connects to the RED receptacle 7 STE...

Page 5: ...nt with a hotter signal 6 IR Receiver is inoperable Replace Receiver 7 XTRALINK Only RF Amplifier is being used on same COAX Line anywhere between the Coupler CPL94 and Injector INJ94 Need to use a By...

Page 6: ...a staple driven through the Signal and GND wires of the IR Receiver and or the emitter Recheck your wiring 2 Emitter may be shorted internally Replace Emitter or use TEST EMITTER to check circuit 3 XT...

Page 7: ...ve Lead on the terminal marked 12VDC or V You should get a reading between 11 5VDC and 13 0VDC If not remove the supply from the Connecting block and measure again this time directly on the 2 5mm Coax...

Page 8: ...ial damages Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you This warranty gives you specific legal rights You m...