Symptom #3: TB LED on IR Receiver (and/or Emitters) on solid 

   Cause: 

Solution 

1.  Plasma Interference 

Use a 85 or 95 series Plasma 'Friendly' 
Receiver. If already using a this unit, please 
note the Plasma interference can be reflected 
off of any item it comes into contact with within 
approx. 3ft. From the front of the display. 
Keeping this in mind, make sure that the IR 
receiver is free from any obstruction that might 
reflect back into the receiving eye. 

2. 

Voltage and Ground wires are 
reversed
 at the connecting 
block or IR Receiver 

Recheck your wiring. 

3. 

Relatively high levels of 
ambient noise. This can be 
due to any of the following: 
Sunlight, florescent Lighting or 
Plasma Displays.  

In this case use either a SUN filter (SUNKIT), 
or any of our ‘Plasma/CFL Friendly’ IR 
Receivers (DL85/95, HL85/95, ML85/95, 
WL85/95).  These can also be used in direct 
sunlight and in the presence of ‘tube style’ 
fluorescent lighting. 

4. 

EMI induced noise. This can 
be due to light dimmer controls 
or other radiating electronic 
devices (PC’s or any poorly 
shielded electronic device).  

Reposition IR Receiver and/or cabling away 
from emitting device. You can also place a 
470Ohm resistor in parallel with the IR Signal 
and GND connections on the connecting 
block. This will also help alleviate any stray 
capacitance in the cable. 

5. 

Power Supply not putting out 
proper voltage.  

Verify supply is a 12VDC regulated supply 
reading between 11.5 to 13VDC under load. 

 

 

11 

 

Symptom #4: TB LED on IR Rec. blinks but 283D or 286D 'Blink' 
style Emitters do not 

   Cause: 

Solution 

1. 

There may be a short, such as a 
staple driven through the Signal 
and GND wires of the IR 
Receiver and/or the emitter. 

Recheck your wiring. 

2.  Emitter may be shorted internally 

Replace Emitter or use TEST EMITTER to 
check circuit. 

(XTRALINK Only) TV on same 
splitter with no IR Receiver 
installed 

Place a DC Blocker (Model 203-00) on 
any TV Leg without IR Receiver 

 
 

 

 

Symptom #5: Intermittent IR control (I.e. buttons on remote need to 
be pressed multiple times) 

   Cause: 

Solution 

1.  Plasma Interference 

Use a 85 or 95 series Plasma 'Friendly' 
Receiver 

2. 

Relatively high levels of ambient 
noise
. This can be due to any of 
the following: Sunlight, florescent 
Lighting or Plasma Displays.  

In this case use either a SUN filter 
(SUNKIT), or any of our ‘Plasma/CFL 
Friendly’ IR Receivers (DL85/95, HL85/95, 
ML85/95, WL85/95).  These can also be 
used in direct sunlight and in the presence 
of ‘tube style’ fluorescent lighting. 

3. 

Long Wire Runs – shielded wire 
typically of 100 feet (30 meters) 
or longer causes a filter effect 
due to accumulated capacitance 
of the wire.  Intermittent, or no IR 
control, could actually be 
because of the longer wire runs.  

Putting a 470-ohm resistor in parallel at 
the connecting block between signal and 
ground will effectively discharge the 
capacitance of the wire.  This will allow the 
signal to travel farther on shielded wire.    
Adding a resistor between the input and 
ground of the connecting block will drop 
the IR level down somewhat.  Passive 
connecting blocks, such as the 789-44, 
may not have enough signal output for 
consistent control of the equipment.  You 
may have to upgrade to an amplified 
connecting block to bring the IR level back 
to normal.  In these cases, the 791-44 
would be an ideal connecting block for 
single zone systems while the 795-20 
would work best for a 2-4 zone system. 

 

Summary of Contents for ML85K

Page 1: ...eter hole 2 inches deep 50mm Quick Connect 3 5mm Stereo Mini Plug on 7ft cable for direct plug in to Xantech Connecting Blocks Works in normal 3 wire mode 12VDC IR GND Green Talkback LED for System Ve...

Page 2: ...not long enough Simply cut off the mini plug strip the leads and splice them to a 3 conductor extension cable with a terminal block or other means Then connect the extension cable to the 3 or 4 termin...

Page 3: ...IR Photodiode Talkback LED 791 44 Amplified Connecting Block 12 VDC GN D EMITTERS 12 VDC HIGH IR OUT ST ATUS I R IN IR RCVR 791 44 AMPLIFIE D CONNECTING BLOCK 781ERGPS Emitter 5 1 Micro Link ML IR Re...

Page 4: ...let STEP 2 Connect the 3 5mm stereo mini plug from the 481D IR Receiver ITEM A to the IR RCVR input located on the 789 44 Connecting Block ITEM B The RED connector connects to the RED receptacle 7 STE...

Page 5: ...nt with a hotter signal 6 IR Receiver is inoperable Replace Receiver 7 XTRALINK Only RF Amplifier is being used on same COAX Line anywhere between the Coupler CPL94 and Injector INJ94 Need to use a By...

Page 6: ...a staple driven through the Signal and GND wires of the IR Receiver and or the emitter Recheck your wiring 2 Emitter may be shorted internally Replace Emitter or use TEST EMITTER to check circuit 3 XT...

Page 7: ...ve Lead on the terminal marked 12VDC or V You should get a reading between 11 5VDC and 13 0VDC If not remove the supply from the Connecting block and measure again this time directly on the 2 5mm Coax...