background image

User Manual 

Automotive Ethernet Converter 

18 

Appendix 

Technical specifications 

Dimensions (H x W x D) 

21 mm x 56 mm x 104 mm 

Supply voltage 

6 V to 28 V 

Current consumption 

max 150 mA (at 12 V) 

Current consumption (standby) 

max 1 mA (at 12 V) 

Data rate 

up to 1000 Mbit/s 

Temperature range 

-40 °C to +60 °C 

 

Pin assignments 

The connectors of the provided connection cable have the following pin assignments. 

 

Pin 

Function 

CAN_H 

CAN_L 

KL30(Ubatt) 

KL31(GND) 

OABR_N 

OABR_P 

 

 

Pin 

Function 

CAN_L 

CAN_H 

 

CAN 

 

 

 

Pin 

Function 

OABR_N 

OABR_P 

 

OABR 

 

 

 

Colour 

Function 

red 

KL30(Ubatt) 

black 

KL31(GND) 

 

Ubatt/GND 

 

Summary of Contents for Automotive Ethernet Converter

Page 1: ...Automotive Ethernet Converter User Manual Version 1 12 September 2021...

Page 2: ...Reproduction of this user manual even in part is only permitted with the approval of X2E GmbH Any infringement will result in liability for damages and may result in criminal prosecution All product n...

Page 3: ...5 Identification 7 Connections and controls 8 Installation 11 Mounting 11 Connecting 11 Configuration and firmware update 13 Install XORAYASuite 13 Start Gateway configuration 14 Connect converter 15...

Page 4: ...gger on the other You may only operate the converter within the scope of the technical specifications provided in this user manual Additionally the use in hazardous areas is not allowed Delivery conte...

Page 5: ...ge Electronic components can be destroyed by electrostatic discharge Avoid touching connectors and connector pins Ground yourself before carrying the converter in your hands Operate the converter in a...

Page 6: ...quipment and receiver Connect the equipment into an outlet on a circuit different from that to which the re ceiver is connected Consult the dealer or an experienced radio TV technician for help Change...

Page 7: ...re Functions described in this user manual correspond to the Automotive Ethernet Converter AEC at the following development stage hardware revision 1 03 firmware version 04 02 00 XORAYASuite version 0...

Page 8: ...ack side Front view Back view Link LED for 100 1000Base T1 A Colour Meaning green link established also USB bootloader mode depending on version Connection for power 100 1000Base T1 and CAN B Pin Func...

Page 9: ...hite since FW 04 02 00 converter ready and in legacy mode red error on Ethernet interface red blinking error on 100 1000Base T1 interface off USB bootloader mode LED for CAN E Colour Meaning blue inte...

Page 10: ...between master up or slave down 2 switch the data rate between 1000 Mbit up and 100 Mbit down 3 activate up or deactivate down sleep wake mode via CAN Reset button J This button is used to restart th...

Page 11: ...e to improper connection Introducing the 4 mm plugs of the supplied connection cable into low volt age sockets can be fatal Never introduce the 4 mm plugs into low voltage sockets CAUTION Device damag...

Page 12: ...to 0 V or ground Connect the red cable labelled KL30 Ubatt to a DC power supply in the specified range Ensure that all connectors are firmly attached and tighten the screws where possible Turn on the...

Page 13: ...compatible with older X2E converters general compatibility with other automotive Ethernet components not guaranteed Compliant general compatibility with other automotive Ethernet components Mutual exc...

Page 14: ...uite installation wizard and follow the instructions Make sure that the components Gateway configuration and DFU Driver are selected Start Gateway configuration Start the XORAYASuite Click in the Wind...

Page 15: ...by a blue border around the icon Click to get information about the connected converter firmware version current configuration etc Change configuration Click to load the current configuration from the...

Page 16: ...Otherwise the converter stays in USB bootloader mode and it is not con verting data After the successful transfer the converter switches back into standard mode which is indi cated by green illuminat...

Page 17: ...e converter Maintenance and repair must be carried out by X2E personnel only In case of malfunctions or damages please contact X2E via e mail to get information about returning the converter xoraya re...

Page 18: ...nt consumption standby max 1 mA at 12 V Data rate up to 1000 Mbit s Temperature range 40 C to 60 C Pin assignments The connectors of the provided connection cable have the following pin assignments Pi...

Page 19: ......

Page 20: ......

Page 21: ......

Page 22: ...X2E GmbH Grosse Ahlm hle 19 76865 Rohrbach GERMANY Phone 49 6349 99599 200 E Mail xoraya x2e de Internet www x2e de...

Reviews: