seconds.
60 seconds
independent
warning.
Malfunction
Red LED flashes
twice every 40
seconds.
2 beeps every
40 seconds
Each alarm
gives an
independent
warning.
Silence Mode
If you press the silence button during an alarm state, the unit will be in the silence mode for 9 minutes.
During the silence mode, the red LED will flash once every 5 seconds. The alarm will enter the normal
mode after 9 minutes.
NOTES
1.
You can silence all interconnected units by pressing the test/silence button on one of the smoke
alarms. If one unit is still alarming, it is the initiating smoke alarm (the unit that detected the
smoke); to silence all connected units, you must also press the test/silence button on the
initiating smoke alarm.
2.
While interconnected, the initiating smoke alarm cannot be triggered again during the 9-minute
silence duration. However, all other interconnected alarms can be triggered again if they detect
dangerous smoke levels during the silence mode.
Technical Specifications
Power Supply
10-year sealed lithium battery
Sensor Type
Photoelectric
Safety Standards
EN 14604:2005+AC:2008
Coverage Area
215-430 sq. ft (20-40 m²)
Operating Temperature
40-100°F(4.4-
37.8℃
)
Operating Relative Humidity
≤ 85% (non
-condensing)
Alarm Loudness
≥ 85 dB at 10 ft (3 m) @ 3.2 ± 0.3 kHz pulsing alarm
Silence Duration
About 9 minutes
Operating Frequency
915 MHz