Technical Specifications
Silence Mode
Flashes red 4 times
every 6 seconds.
None.
CO silence mode: After 9
minutes, the unit will exit
silence mode.
Flashes yellow once
None.
Silence mode during low
every 60 seconds.
battery: after 10 hours, the unit
will exit silence mode.
Flashes yellow 3 times
None.
Silence mode during the end of
every 60 seconds.
cycle: after 22 hours, the unit
will exit silence mode.
Flashes green 3 times.
None.
Exiting silence mode.
Low Battery
Display alternates between
"Lb" and current CO level.
The LED indicator flashes
yellow once every 60
seconds.
1 quick beep
every 60
seconds.
XC01/XC05P: The unit must be
replaced immediately.
XC01P-R: The battery must be
replaced immediately.
Fault
Flashes yellow 2 times
every 60 seconds.
2 beeps every 60
seconds.
Please clean your alarm and see if it is
working normally. If "Err" continues to
display, the unit has malfunctioned
and must be replaced immediately.
End of Life
Flashes yellow 3 times
every 60 seconds.
3 quick beeps
every 60 seconds.
Replace the unit immediately.
Power Supply
XC01/XC05P: 10-year sealed lithium battery
XC01P-R: CR123A or CR2/3A (replaceable battery)
Product Lifespan
10 years
Sensor Type
Electrochemical