Light Source

Light Source

There are two different light sources provided by the objective lens of
X-Loupe® G Series: coaxial lighting (MAIN) and low-angled lighting (SUB).
The coaxial lighting, located on the inner circle, is the direct-projection light 
coming out from 8 LEDs; whereas the low-angled lighting, located on the outer 
circle, is the lower-angled projection light coming out from the other 8 LEDs. 
The brightness indexes of both lighting are adjustable from zero to 5. The 
factory default setting of both lighting are ON and brightness index are set to 5.

Switch Button for Lighting Setting

【●】

Coaxial Lighting (MAIN)

 

【○】

Low-Angled Lighting (SUB)

 

【⊕】

Quadrant Setting of Low-Angled Lighting (SUB)

Tune Button

Adjust the brightness index of lighting by tuning the button up and down. By 

pressing the Tune Button, the brightness index becomes '3'. The quadrant 

setting of Low-Angled Lighting (SUB) is also controlled by the Tune Button 

when switch to Quadrant Setting of Low-Angled Lighting 

. By pressing 

the Tune Button, the light of upper left and right quadrants turns on.

Switch Button for Coaxial Lighting

There are 3 kinds of light sources: W (White), F( Functional Illumina tion), 

and W+F (White + Functional Illumination).1

When the coaxial lighting is switched to W (White), 'W' is shown on the 

LCD monitor; whereas 'F' is shown when switching to F (Functional 

Illumination).1

In conventional micro-photography, taking a good picture is so difficult that most
users have to be content with pictures of less-than-expected quality. G Series
change the situation. Equipped with 2 different light sources (coaxial lighting 
and low-angled lighting), G Series provide more than 10 different lighting 
options. The flexible lighting options provide the capability to capture high-
quality pictures for various and changeful subjects. Please refer to the following 

operation steps.

(1) Turn ON coaxial lighting; Turn OFF low-angled lighting.

Steps

1

2

4

5

6

Selection

Switch Button for Lighting 

Setting

Tune Button

Switch Button for 

Lighting Setting

 Tune Button

Switch Button for 

Coaxial Lighting

Illustration

Description

Switch to Quadrant

Setting of Low-Angled 

Lighting

Turn off ligh of all

quadrants

Switch to Coaxial

Lighting (MAIN)

Tune the brightness

index as desired (1~5)

(Check LCD monitor)

To switch between 4 

and 8 LEDs.2

1.F (Functional Illumination) is optional and for the special order only, such as Ultraviolet Light.Unless otherwise 

mentioned, each objective lens is equipped with white-colored LED by default.

2.By default, the coaxial lighting is supported by 8 LEDs. Switching to W+F will turn on all 8 LEDs, while W or F only 

turns on 4 LEDs. By special order, the coaxial lighting can be equipped with 4 white-light LEDs and 4 Functional 

Illumination LEDs.

The picture shown here is lighting

with 4 white-light LEDs.

Summary of Contents for G-series

Page 1: ...English Digital Portable Microscope User s Guide...

Page 2: ...US7 327 526 B1 US7 821 569 B2 US7 853 137 B2 Nr 20 2007 014 240 4 Nr 20 2006 001 999 5 China Patent No Japan Patent No Taiwan Patent No US Patent No Germany Patent No In the interest of continually im...

Page 3: ...anon digital camera IXUS 800IS 950IS Enjoy photography and micro photography with one single X Loupe For more information and downloading this user guide please visit our website at http www x loupe c...

Page 4: ...dule Power Switch Components Components Front View Upper View LCD Monitor Back View Digital Camera Exchangeable Objective lens Light Source of Objective Lens LCD Monitor Switch Button for Coaxial Ligh...

Page 5: ...the battery charger CB 2LX into the power outlet or attach the power cord to the battery charger CB 2LXE and plug it into a power outlet The charger indicator will light on Orange charging the batter...

Page 6: ...hereas F is shown when switching to F Functional Illumination 1 In conventional micro photography taking a good picture is so difficult that most users have to be content with pictures of less than ex...

Page 7: ...g Tune the brightness index as desired 1 5 Check LCD monitor Switch to Quadrant Setting for Low Angled Lighting Select which quadrants to turn on Light Source Light Source 3 Turn ON low angled lightin...

Page 8: ...ve lens with the other red dot on the module Attach the objective lens to the module Rotate the objective lens clockwise until the sound ka is heard Do not over rotate the objective lens To change the...

Page 9: ...d be carefully revented during shooting Keep rotating the barrel until it is removable from the objective lens Have the contact ring closely touched the surface of the subject Slightly press X Loupe o...

Page 10: ...amera 2 Focus The auto focus function of Canon camera at optical zoom factor 4X is very sensitive and clever However while using a higher zoom factor it is getting harder to focus the subject automati...

Page 11: ...knob of the stand and taking the pictures as desired Please refer to IXUS 950IS Advanced Camera User Guide P 51and P 52 3 Continuous Shooting and Self Timer To take pictures for a living thing such a...

Page 12: ...ject the conventional microscopy Sometimes moving X Loupe up and down a little bit can reach the best focus The AF autofocus green frame s on the LCD means good focus whereas orange means close to the...

Page 13: ...Timer To reduce the influence of vibration during shooting please use Self Timer for better performance refer to PowerShot 110HS User Guide Page 58 5 Single shooting is the default setting In a circu...

Page 14: ...utton the tint on the screen will change when WB new data is set Note It is useless to adjust WB while the light source is in the mode of Blue UV or using the lens filter It s another way for Manually...

Page 15: ...roubleshooting of IXUS camera please refer to the Adva nced Camera User Guide of IXUS 2 The LED in the objective lens is not bright a Check the battery power b Disassemble the objective lens and assem...

Page 16: ......

Page 17: ...page 30 page 31 MEMO MEMO...

Page 18: ...oor No 8 Wanhe St Wenshan District 116 Taipei City Taiwan R O C TEL 886 2 2230 1168 FAX 886 2 2239 2112 e mail x loupe lumos com tw http www x loupe com http www lumos com tw Digital Portable Microsco...

Reviews: