background image

台北市

116

文山區萬和街

8

7

7th floor, No.8, Wanhe St., Wenshan District, 
116 Taipei City, Taiwan, R.O.C.
TEL:886-2-2230-1168    FAX:886-2-2239-2112
e-mail:[email protected]
http://www.x-loupe.com    http://www.lumos.com.tw

可攜式顯微鏡相機

English

Digital Portable Microscope

可攜式顯微鏡相機

User’s Guide 

使用指南

Digital Portable Microscope

User’s Guide 

使用指南

Summary of Contents for G-series

Page 1: ...English Digital Portable Microscope User s Guide...

Page 2: ...US7 327 526 B1 US7 821 569 B2 US7 853 137 B2 Nr 20 2007 014 240 4 Nr 20 2006 001 999 5 China Patent No Japan Patent No Taiwan Patent No US Patent No Germany Patent No In the interest of continually im...

Page 3: ...anon digital camera IXUS 800IS 950IS Enjoy photography and micro photography with one single X Loupe For more information and downloading this user guide please visit our website at http www x loupe c...

Page 4: ...dule Power Switch Components Components Front View Upper View LCD Monitor Back View Digital Camera Exchangeable Objective lens Light Source of Objective Lens LCD Monitor Switch Button for Coaxial Ligh...

Page 5: ...the battery charger CB 2LX into the power outlet or attach the power cord to the battery charger CB 2LXE and plug it into a power outlet The charger indicator will light on Orange charging the batter...

Page 6: ...hereas F is shown when switching to F Functional Illumination 1 In conventional micro photography taking a good picture is so difficult that most users have to be content with pictures of less than ex...

Page 7: ...g Tune the brightness index as desired 1 5 Check LCD monitor Switch to Quadrant Setting for Low Angled Lighting Select which quadrants to turn on Light Source Light Source 3 Turn ON low angled lightin...

Page 8: ...ve lens with the other red dot on the module Attach the objective lens to the module Rotate the objective lens clockwise until the sound ka is heard Do not over rotate the objective lens To change the...

Page 9: ...d be carefully revented during shooting Keep rotating the barrel until it is removable from the objective lens Have the contact ring closely touched the surface of the subject Slightly press X Loupe o...

Page 10: ...amera 2 Focus The auto focus function of Canon camera at optical zoom factor 4X is very sensitive and clever However while using a higher zoom factor it is getting harder to focus the subject automati...

Page 11: ...knob of the stand and taking the pictures as desired Please refer to IXUS 950IS Advanced Camera User Guide P 51and P 52 3 Continuous Shooting and Self Timer To take pictures for a living thing such a...

Page 12: ...ject the conventional microscopy Sometimes moving X Loupe up and down a little bit can reach the best focus The AF autofocus green frame s on the LCD means good focus whereas orange means close to the...

Page 13: ...Timer To reduce the influence of vibration during shooting please use Self Timer for better performance refer to PowerShot 110HS User Guide Page 58 5 Single shooting is the default setting In a circu...

Page 14: ...utton the tint on the screen will change when WB new data is set Note It is useless to adjust WB while the light source is in the mode of Blue UV or using the lens filter It s another way for Manually...

Page 15: ...roubleshooting of IXUS camera please refer to the Adva nced Camera User Guide of IXUS 2 The LED in the objective lens is not bright a Check the battery power b Disassemble the objective lens and assem...

Page 16: ......

Page 17: ...page 30 page 31 MEMO MEMO...

Page 18: ...oor No 8 Wanhe St Wenshan District 116 Taipei City Taiwan R O C TEL 886 2 2230 1168 FAX 886 2 2239 2112 e mail x loupe lumos com tw http www x loupe com http www lumos com tw Digital Portable Microsco...

Reviews: