![Wylie 8220 Boom Operator'S & Parts Manual Download Page 17](http://html1.mh-extra.com/html/wylie/8220-boom/8220-boom_operators-and-parts-manual_1001705017.webp)
13
With the Mix n’ Fill ball valve closed, add the desired
amount of chemical to the Mix n’ Fill tank. Open the agitator
and return lines, then engage the pump. Close the spray
tank ball valve about halfway to “starve” the pump slightly.
Operation
HCS-500T Trailer Mix-n-Fill:
Pull the lock pin and lower the Mix-n-Fill tank. Place lock
pin back in the frame so that the tank stops in the correct
horizontal position.
Assure that the Mix-n-Fill ball valve
is closed
.
The Mix n’ Fill tank should always be empty except
when adding chemical to the sprayer. Raising and low-
ering the tank with chemical is dangerous and greatly
increases the possibility of chemical exposure to your
body resulting in sickness, injury or possibly death.
Figure B8
Adding Chemical to Mix-n-Fill Tank
< spray tank valve
< fresh water valve closed
< return valve open
agitator valve open >
Figure B4
EP-1000 Valve Setting for Chemical Induction
Figure B5
EP-1000 Chemical Induction
Figure B6
Removing Lock Pin from Mix-n-Fill Tank
Figure B7
Lowering Mix-n-Fill Tank
Figure B7
Adding Chemical To Mix-n-Fill Tank
lock pin >
Mix n’Fill valve closed >
open Mix-n-Fill valve >