background image

21

Equipment Compatibility

The following is a chart of compatibility and capacity of the various models of Coloram II 
Power Supply and the companion components.

Max # of

Power Supply

Model

Output

Channels Max # of

Max # of

Max # of

Max # of

Description

Number

Power

Available

CXI (2)

Coloram (3) Eclipse (4) Goboram (5)

6-Way

19060

150 watts

12

3

6

6

4

12-Way

19012

300 watts

24

6

12

12

8

24-Way

19000

600 watts

48

12

24  (1)

24  (1)

16

Notes:
(1) can only use the first 24 channels
(2) CXIs use 1, 2 or 3 channels
(3) Colorams use 1 channel 
(4) Eclipses use 1 channel 
(5) Goboram IIs use 3 channels

Cables

Coloram II Cable

The Coloram II Cable uses 4-pin XLR connectors on either end and consists of  two 14 
AWG conductors and a 22 AWG twisted, shielded pair. The shells of the two XLR 
connectors are not electrically connected together -- this prevents large power currents 
from flowing from chassis to chassis of the Coloram II equipment. The twisted pair 
shield is not connected at either end.

XLR Pin #

Wire Color

Function

Size

1

White

24 Volts DC 14 AWG

2

Green

Data -

22 AWG

3

Red

Data +

22 AWG

4

Black

Ground

14 AWG

Summary of Contents for Coloram II 19000

Page 1: ...Power Supply User Manual...

Page 2: ...tion 4 The Coloram II System 4 The Coloram II System Components 5 Color Changers and Other Components 5 Power Supply 6 Cables 6 The Coloram II Power Supply Menu 7 Menu Tree 7 Menu Details 7 Error Mess...

Page 3: ...es step by step instructions for preparation setup and operation of the Coloram II Power Supply There is a potential risk of fire electric shock or injury to persons if the product is not used as inst...

Page 4: ...oard is connected to the power supply and can continue on to more Coloram II Power Supplies or other DMX controlled devices The power supply sends both power and control signal on a single cable elimi...

Page 5: ...System Components Color changers and other components The color changers set the position of the gelstring via a signal from the lighting console The control signal and DC power 24 VDC are both suppli...

Page 6: ...color changer status Coloram II Cable The Coloram II Cable connects the Coloram II Power Supply outputs to the Coloram II Color Changers or other products and provides them with power and control sig...

Page 7: ...00 DCV 24 Fan NORM Mtr NORM Ver x x CXI IDENTIFY DCV 24 Fan NORM Ver x x OR GLA 0 GLB 0 MEANS PRESS MEANS PRESS BUTTON BUTTON ALERT DETAILS APPEAR HERE X ALERT POWER UP SCREENS RUN SCREEN LOOP Menu De...

Page 8: ...d gel position and the actual gel position VDC xxx Color changer voltage is below 17 volts DC Shut xxx Color changer reports a SHUTDOWN condition will not respond to position commands because the volt...

Page 9: ...t more information on the alerts 4 As an example Pstn 001 indicates the head unit 1 has a position error 5 Press Enter to get information on other alerts 6 Viewing the alerts in this manner also clear...

Page 10: ...t to normal or low Enter Ver x x This tells you the software version installed in the color changer set to the channel you are looking at Enter Identify Pressing will cause the color changer whose sta...

Page 11: ...nger is rotating the carriers toward FL an arrow pointing to the right will be displayed If the gobo changer is rotating the carriers toward 00 an arrow pointing to the left will be displayed Enter Sp...

Page 12: ...is option turns talkback to a remote status monitor on or off Status of the color changers or gobo changers will still be displayed in the status menu If this is turned on the first channel of the pow...

Page 13: ...the option Pressing and will increment and decrement numbers or toggle options Pressing Enter will confirm your selection and the question mark will go away Disp This option allows you to select how...

Page 14: ...options will bring up a question mark behind the option Pressing and will increment and decrement numbers or toggle options Pressing Enter will confirm your selection and the question mark will go aw...

Page 15: ...h a mounting bracket which hooks over the pipe or truss of your lighting rig and is then locked into place with a thumb screw If you have selected this mounting method connect the power supply s safet...

Page 16: ...the software version installed in it The power supply will then initiate a roll call which tells the color changers to check in and initialize the gel string Caution Do not power the power supply fro...

Page 17: ...to the DMX signal until you return in the menu tree to the RUN SCREEN loop 5 Connect and set the DMX512 source Connect the DMX512 signal source to the DMX input connector on the front of the power su...

Page 18: ...orams is 20 feet long The amount of cable from the power supply to 1st Coloram II 100 ft 2nd Coloram II 120 ft 3rd Coloram II 140 ft 4th Coloram II 160 ft total 520 Head Feet Mounting and installation...

Page 19: ...flat surface 3 Position the brackets as shown below 4 Attach the bracket using a 3 16 Allen wrench and the supplied screws Note Use the supplied thumb screws to clamp the hanger brackets to the desire...

Page 20: ...install the power supply into the rack mounting tray 1 Disconnect AC power from the power supply 2 Place the rack mount tray right side up on a flat surface 3 Position the power supply in the rack mo...

Page 21: ...first 24 channels 2 CXIs use 1 2 or 3 channels 3 Colorams use 1 channel 4 Eclipses use 1 channel 5 Goboram IIs use 3 channels Cables Coloram II Cable The Coloram II Cable uses 4 pin XLR connectors on...

Page 22: ...upply model 19000 7 amp slo blo at 115 VAC 4 amp slo blo at 230 VAC 12 Way Power Supply model 19012 4 amp slo blo at 115 VAC 2 amp slo blo at 230 VAC 6 Way Power Supply model 19060 2 amp slo blo at 11...

Page 23: ...el shown will be the last channel used by the power supply for talkback 5 In the CRI mode the power supply can control more color changers on separate channels 6 Increased the highest starting channel...

Page 24: ...3 power signal cable 7042 5 5 power signal cable 7042 10 10 power signal cable 7042 15 15 power signal cable 7042 25 25 power signal cable 7042 50 50 power signal cable 7042 75 75 power signal cable 7...

Page 25: ...or any incidental general or consequential damages to property damages for loss of use time profits or income or any other charges The owner s obligations during the warranty period under this warrant...

Reviews: