Maintenance
General Maintenance
The commutator should be cleaned every two years or every 6000 hours of operation.
Cut/wipe pivot points should be greased (approx. every 6000 hours of operation). See Item 4 below.
Figure 9 Film in clamp
Filter Regulator
The FR possesses a Filter, which traps the water contained in the air line. A drain plug is located at
the bottom of the filter section
. (This function should be done automatically and should not have
to be touched).
The second section of the FR contains a Regulator that shows how much air
pressure going is into the machine. The pressure may be regulated by the knob located at the top of
the center section of the FR. This pressure should be set at 80 psi for all Wulftec automatic
machines.
*For cold package; apply EP0 grease.