Recommended setups

For electric sailplanes:

 

Setup 9 at #4 and setup10 at #0

 

Setup 14: Select current sensor type: 80 A or 150 A or 400 A

 

Optional: Drive battery voltage alarm in Setup 12

 

Optional: Temperature threshold in Setup 11

For electric models:

 

Setup 9 at #5 and Setup 10 at #0 ; all other Setups may remain in their default setting

 

Setup 14: Select current sensor type: 80 A or 150 A or 400 A

 

Optional: Drive battery voltage alarm in Setup 12

 

Optional: Temperature threshold in Setup 11

The pitot-tube airspeed sensor may replace the WSTECH GPS groundspeed sensor for speed
measurements. Setup 4 allows the choice between a single announcement of a maximum speed reading
and a continous mode. The details are described in chapter 7.1.

All these modes and alarms can be configured in the setup procedure.

The sensor interface can either accept the temperature or the pitot-tube sensor from SM-Modellbau.

If the temperature sensor is connected there is a setting above 0° required in Setup 11 in order to activate
the temperature announcement in the vario.

In reverse, if the speed sensor is connected setup 11 must be set to 0 and Setup 10 at #3. The temperature
check and announcement is then suppressed automatically.

13.1  Important Notes about Sensor Interface Operation

 

Only the special 4-pole cable is to be used for connection to the vario.

 

Both connectors do not have a special assignment; they may be used either way

 

The current sensor should not be connected to the motor drive battery before several seconds after
vario start-up

 

Important: Always connect the negative lead first.

 

The sensor interface is powered by the vario

 

The default setup settings provided, there is no need for any setup changes if the sensor interface is
connected together with the GPS module only.

 

With the current sensor connected, Setup 9 must be set accordingly. Otherwise there will be no
announcement of electric drive measurements.

 

Setup 14 has to be set according to the current sensor. Default setting is the 150 A type from SM-
Modellbau.

 

If the sensor interface and the GPS module are connected correctly, the 5

th

 “beep” of the start-up

phase will last longer than the first four and it is followed by two short “beeps”. The vario thus
indicates the detection of the GPS-module and it announces ”sensor interface and GPS detected”

 

When operating the sensor interface without GPS module, there is only one short beep (instead of
two) and the voice output “sensor interface detected”.

14  Notes about CS DataVario Operation together with the UniLog Data Logger

UniLog, current sensor, temperature sensor and speed sensor are products from SM-Modellbau
(www.SM-Modellbau.de) and are available in their online-shop.

The UniLog

 

data logger is connected to the vario with e special 3-lead cable from WSTECH. The 4-pole

COM-port is used on the UniLog side.

If the UniLog is connected, the vario has to be configured for this in Setup 10; otherwise there would be no
data exchange between both units. Even though the vario will recognize lots of settings by itself, it is
mandatory that the user takes care for the following settings when operating the vario with the UniLog:

Summary of Contents for CS DataVario

Page 1: ...e Model Airplane Variometer C CS S D Da at ta aV Va ar ri io o including Micro SD Card Logger GPS Electric Flight and Data Logger Options CS DataVario and mirco SD card for the datalogger CS DataVario...

Page 2: ...1 Selecting the Standby Mode 11 8 Alarms and Alarm Thresholds 11 8 1 Receiver Battery Voltage Check and Alarm 11 8 2 Drive Battery Minimum Voltage Check and Alarm 11 8 3 Temperature Check and Alarm 11...

Page 3: ...rt into many other evaluation software programs is possible The CS DataVario provides important information about the drive system to the electric flyer and allows component tuning and optimization Fo...

Page 4: ...the antenna must not be close to carbon fiber fuselage as this would lead to a very erratic transmission range The antenna should not be parallel to other cables or metallic material as this may alte...

Page 5: ...n be adjusted between 0 ft sec and 6 ft sec in steps of 0 3 ft sec 4 1 Voice output for vario and altimeter In the vario and altimeter function the voice output can deliver either output Altitude Inte...

Page 6: ...makes the integral vario mode a most prefered operating mode particularly in weak conditions 4 3 Total Energy Compensation TEK The CS DataVario provides a port for the connection of a TEK probe a feat...

Page 7: ...sec 5 2 Mode Settings and Voice Output Functions Mode Switch Slider Mode Feedback Voice Output Vario Acoustics Remarks Integral Mode Foreward beep Altitude change since last annoubcement On Glide rati...

Page 8: ...nly a one second beep signals that a measurement is being performed As soon as there is no more speed increase detected after three measurement cycles the previously measured maximum value is being an...

Page 9: ...r material In case the model has a carbon fiber canopy you may want to consider replacing a 1 x 1 section with a glass fiber window Another solution would be to ask the manufacturer for a replacement...

Page 10: ...mode is selected the standard announcement of present altitude and R C battery voltage is complemented by the announcements of the idle drive battery voltage and the values selected in Setup 9 7 1 2...

Page 11: ...d Alarm Thresholds 8 1 Receiver Battery Voltage Check and Alarm The actual receiver voltage which also supplies the vario is continuously checked by the vario electronics After start up the first valu...

Page 12: ...current falls below 3 A 10 Max min value Storage Independant from the data logger feature the following max min values are stored in a non volatile memory Standard is the maximum altitude and minimum...

Page 13: ...nt memory card detected confirms the presence of the memory card If a setup file SETUPUPL HEX is recognized on the memory card the vario will use it from thereon and confirm it by setup detected The v...

Page 14: ...motor drive battery before several seconds after vario start up Important Always connect the negative lead first The sensor interface is powered by the vario The default setup settings provided there...

Page 15: ...must be no 4 lead cable used for the connection between the vario and the UniLog only the 3 lead cable provided with the delivery There is no special assignment for the plugs The cable may be used in...

Page 16: ...bove the take off altitude Altitude announcement time interval between 10 sec and 120 sec default 60 sec In the electric flight mode Setup 10 5 the time interval determines the announcement sequence f...

Page 17: ...rom SM Modellbau 1 40 80 A sensor 2 150 A sensor default 3 400 A sensor Setup 15 Announced units in meters or feet 0 Feet 1 Meters default 16 1 Setup Storage on the Memory Card If a memory card is pla...

Page 18: ...the applications described in this manual Also note the safety notes and manuals of equipment to which this equipment is connected to The manufacturer does not take any responsibility for either damag...

Page 19: ...rent sensors from SM Modellbau Temperature respectively speed sensor port for SM Modellbau sensors Size typical 17 mm x 31 mm x 7 mm Power supply from vario Technical Data of the GPS module with integ...

Page 20: ...nden Richtlinien und Normen bereinstimmt R TTE Richtlinien 99 5 EG Norm EN 300 220 1 Ausgabe November 1977 Diese Erkl rung wird abgegeben von Wolfgang Schreiner wstech Oberteuringen 5 5 2006 wstech Wo...

Page 21: ...move to above or below menu option Right Red button Confirm sound level select menu option PTT button Transmit Call button Sound bell on other LPDs set to same configuration Battery Installation Loos...

Page 22: ...move the jack socket s protective cover next to the antenna and plug in the earpiece s jack plug Adjusting the Volume To adjust the volume press the left green key and use the arrow keys to increase o...

Reviews: