Modular Matrix Switcher 16x16
31
Example: “USER/I/7:0623%;” to set the input 7 to support YPbPr signal, the card is
plugged in the second input slot of the matrix.
4.4. TCP/IP Control (Optional)
4.4.1. Control Modes
TCP/IP default settings: IP is 192.168.0.178, Gateway is 192.168.0.1, and Serial
Port is 4001. IP & Gateway can be changed as you need, Serial Port cannot be
changed.
l
Controlled by Single PC
Connect a computer to the TCP/IP port of the Modular Matrix Switcher 16x16, and
set its network segment to the same as the default IP of the Modular Matrix Switcher
16x16 (192.168.0.178).
l
Controlled by PC(s) in LAN
The Modular Matrix Switcher 16x16 can be connected with a router to make up a
LAN with the PC(s), this make it able to be controlled in a LAN. When control, just
make sure the Modular Matrix Switcher 16x16’s network segment is the same with
Same network
segment as the
switcher