2
1.
Locate
wood
stud
where
left
side
of
changing
station
will
be
mounted
to
the
wall.
2.
Measure
up
57.5
”
(
146
cm)
from
the
floor
and
mark
the
wall.
This
locates
the
position
for
the
top
left
attachment
hole.
NOTE:
Mark
on
wall
MUST
be
in
center
of
wood
stud.
3.
Align
hole
in
top
left
corner
of
changing
station
with
mark
on
wall
and
hold
in
place.
4.
Using
a
level
and
measuring
tape,
mark
the
remaining
three
(3)
holes.
After
marking
holes,
set
changing
station
down
on
ground.
5.
Use
a
power
drill
and
appropriate
bit
to
drill
four
(4)
holes
in
the
wall.
This
may
require
2
people.
NOTE
1:
For
wood
studs:
- If
finished
wall
surface
is
tile
or
masonry
over
wood
studs,
use
a
7/32”
masonry
bit
for
the
pilot
hole
until
you
hit
the
wood
stud,
then
change
to
1/8”
bit.
- Use
wood
screws,
finishing
washers
and
flat
washers
(Fig.
a)
NOTE 2: For use with toggles:
- If finished wall surface has wood studs that are not 16” on center,
has metal studs, or has an underlying surface of concrete block,
use 1/2” bit.
- Use machine screws and flat washers
(Fig. b)
.
- For holes NOT located in a wood stud, toggle anchors MUST be
used
(Fig. c)
. See “Using Toggle Anchors” section.
6. Align holes in changing station with drilled holes and secure top left corner of changing
station to wall stud using the appropriate screw and washer. Continue to secure the three (3)
remaining corners using the appropriate screws and washers as described in
Note 1
or
Note 2
.
7. Ensure all four (4) screws are tight and snap caps over screw heads.
Using Toggle Anchors:
1. Insert metal end of toggle anchor into 1/2” hole.
2. Slide zip strip down snugly against wall.
3. Snap off break-away pieces of toggle anchor
(Fig. d)
.
4. Align holes in changing station with toggle anchors and secure top left corner of
changing station to wall using machine screws and flat washers. Continue to secure
the three (3) remaining corners using machine screws and flat washers.
5. Ensure all four (4) screws are tight and snap caps over screw heads.
INSTALLATION
•
A stud MUST be located and used for at least one side of the diaper changing station.
•
The diaper changing station is no stronger than the anchors or walls to which they are attached and, therefore, MUST be
firmly secured in order to support the weight they are intended to support. Contact an architect or building contractor
if any questions.
WARNING
Fig. a
Fig. b
Fig. c
Toggle
Anchor
Flat
Washer
Machine
Screw
Changing
Station
Changing
Station
Finishing
Washer
Wood
Screw
Wood Stud
Wood Stud
Fig. d
Wood Stud
Toggle
Anchor
Break-Away
Flat
Washer
•
All 4 of these locations MUST be used for safe installation. The lower holes ensure
installation through the metal brackets.
WARNING