Workzone 59905 User Manual Download Page 2

Contents

QR codes take you where you want to go 

quicky and easily

Whether you require product information, spare parts or accessories, 
details on warranties or aftersales service, or if you want to watch 
a product demonstration video, our QR codes will take you there in 
no time at all.

What is a QR code? 
A QR-code (QR=Quick Response) is a type of matrix that can be read 
with a smartphone camera and that contains a link to a website or  
contact details, for example. 
Advantage: You are not required to manually enter a website address 
or contact details.

How it works 
To scan the QR code, all you need is a smartphone with QR codes reader 
software and an Internet connection*. This type of software can be 
downloaded for free from your smartphone’s app store.

Try it out now 
Just scan the QR code with your smartphone and 
find out more about the Aldi product you have 
purchased*.

* Depending on your tariff you may be charged for the connection.

Product

Info

For Know How Videos, click on the 

“Product Assistance” tab, then the 

“How To Product Videos” link.

Pack contents / parts  

2

Intended use of the 3600W Inverter Generator with Pure Sine Wave  

2

Contents of carton  

2

Description of symbols  

3

General safety warnings  

4

Additional Safety Rules for Petrol Products  

6

Risk of electrocution and fire  

8

Risk of fire  

9

Risk of injury and property damage when transporting generator  

10

Risk of breathing – inhalation hazard  

10

Risk of unsafe operation  

10

Risk of hot surfaces  

11

Risk of moving parts  

11

Risk from lifting  

11

Parts List  

12

Inverter technology  

14

Operating Periods   

14

240V AC Connection   

14

Other combinations   

15

Assembly / Compact Stand Alone Assembly   

16

Portable Wheeled Typed Generator Assembly   

17

Assembly of the Main carry handle  

18

Indicators  

19

Preparing the Generator  

20

Checking the Engine Fuel  

20

Checking the Engine Oil  

21

Engine Oil Replacement  

22

Starting your Generator / Starting the Engine  

23

Overload Condition   

26

Normal Procedure for Stopping the Engine  

27

Overload procedure for restarting and resetting the engine  

27

Emergency Stop, and / or failure of On/Off switches  

28

Carbon build up    

28

Periodic Maintenance  

29

Generator Maintenance  

30

Storage   

30

Spark Plug  

31

Air Filter  

32

Fuel Tank Filter  

33

Tap Outlet Fuel Filter  

34

Cleaning  

35

Warranty  

35

Environmental protection  

36

What your 3 year warranty means  

36

Service Support  

37

Troubleshooting  

37

Specifications  

39

Summary of Contents for 59905

Page 1: ...ITH PURE SINEWAVE User Manual Product Info www powertoolsupport com Read all safety warnings and all instructions thoroughly before operating this product Ensure you keep your manual in a safe place for future reference IM Ed7 03 2018 ...

Page 2: ...00W Inverter Generator with Pure SineWave 2 Contents of carton 2 Description of symbols 3 General safety warnings 4 Additional Safety Rules for Petrol Products 6 Risk of electrocution and fire 8 Risk of fire 9 Risk of injury and property damage when transporting generator 10 Risk of breathing inhalation hazard 10 Risk of unsafe operation 10 Risk of hot surfaces 11 Risk of moving parts 11 Risk from...

Page 3: ...rge protector connected to the generator NOTE This petrol Generator is NOT suitable for Marine applications and should never be used on board water craft Continuous off the grid power Contents of carton 1 x 3600W Inverter Generator 1 x Instruction Manual 1 x Warranty Card details 1 x Quick Start Guide 1 x 10mm Tube Spanner 1 x 21mm Spark PlugTube Spanner 1 x Multi Size Spanner 1 x Double Ended Scr...

Page 4: ...g power tools with your finger on the switch or energising power tools that have the switch on invites accidents d Remove any adjusting key or wrench before turning the power tool on A wrench or key left attached to a rotating part of the power tool may result in personal injuries e Do not overreach Keep proper footing and balance at all times This enables better control of the power tool in unexp...

Page 5: ...n operation Ensure bystanders also keep their distance Additional Safety Rules for Petrol Products Locate the generator for use in a convenient place so as to use the shortest extension lead as possible but still sufficiently away from the exhaust fumes Ensure the generator has oil Before commencing the generator ensure that the unit has been filled with SAE 10W 30 4 stroke oil Any extension cable...

Page 6: ...echanical or electrical problem Have unit repaired by an Authorised Service Centre Do not operate generator with protective guarding removed Risk of fire Hazard What could happen How to prevent it Attempting to fill the fuel tank while the engine is running Fuel and fuel vapours can become ignited by coming in contact with hot components such as the muffler engine exhaust gases or from an electric...

Page 7: ...and understand all of the operating instructions and warnings in this manual Become familiar with the operation and controls of the generator Know how to shut it off quickly Equip area of operation with a fire extinguisher certified to handle fuel fires Keep children or others away from the generator at all times Operating generator while suspended Generator will not operate properly and will caus...

Page 8: ...ndicator light 9 Power Supply indicator light 10 Muffler 11 Exhaust spark arrestor 12 AC sockets X3 13 Fuel drain 14 Control panel 15 Oil Filler cap dipstick 16 Oil drain plug 17 Ground frame terminal 18 Recoil starter 19 Choke lever 20 Air filter cover 21 Air Filter 22 Spark plug lead cover 23 Spark Plug 24 Tap outlet 25 Fuel tap sediment cap 26 Fuel tap lever 27 Fuel tank inlet filter 28 Feet x4...

Page 9: ...ding televisions computers laptops caravans etc It comes fitted with 3 x 240V AC outlets giving you the ability to run 3 x electrical appliances at the one time as long as the combination of the maximum rating of each appliance does not exceed the maximum rated power of the generator The maximum operational combination on this generator is 3400W For a short period to aid appliances plugged in star...

Page 10: ...be spanner 31 to secure the bolt head in position apply the nut onto the end of the bolt and tighten in a clockwise direction using the multi size spanner 33 Fig G Repeat for the second wheel F G E General Assembly General Assembly This generator has been designed to be used as a stand alone compact generator or a larger portable wheeled type generator Compact Stand Alone Assembly Assembly of the ...

Page 11: ...overheated caused by high temperature c Flashing 3 times indicates overload protection caused by an excessive electrical overload d Flashing 4 times indicates there is an electrical problem most likely caused by a short circuit L M Following assembly of the wheels it is recommended to assemble the additional wheel foot 3 for stability and to keep the generator on a level surface 1 Raise the opposi...

Page 12: ...Oil NOTE Damage to the engine is not covered under warranty if the engine is run with insufficient oil 1 Before checking or refilling oil be sure the generator is put on a stable and level surface ensuring the engine has been switched OFF 2 Remove the oil filler cap 15 by rotating the cap in an anti clockwise direction and wipe all oil residue off the oil dipstick 15 with a clean rag Re insert the...

Page 13: ...hen the oil level is close to the low level Fill the oil tank before use each time 4 If the oil is contaminated or has discoloured ensure you change the oil Replace the oil dipstick 15 DO NOT start the generator with the oil dipstick 15 not firmly replaced NOTE This engine is fitted with a low oil indicator light 7 If the oil level is too low the engine will stop operating or the engine will not s...

Page 14: ...e On Off switch 4 to the ON green position as indicated by an I down Fig U This generator will not start without this switch in the ON position 5 To start the engine slowly pull the recoil starter 18 until you feel it engage and then pull it briskly Fig V When starting the engine for the very first time it may require a number of attempts to start until the fuel has travelled from the tank to the ...

Page 15: ...nue to supply 240Va c output for a very short time but if the load is not reduced the 240V supply will be automatically shut down To reduce load firstly you can stop using one appliance and turn it off see if that rectifies the problem If not refer to page 14 on loading s and how they work If this does NOT solve your problem you will need to reset an overload condition and shut down the engine of ...

Page 16: ...be a problem on generators as the loading on the engine can vary considerably Running the generator at low loading for extended periods can cause carbon build up Carbon build up in the engine can be reduced by operating the generator at approximately 75 of rated load for 25 of the time the generator is used i e if the generator is used for 4 hours on low load i e 800W or less run the generator for...

Page 17: ... the fuel totally from the fuel tank 1 Check the fuel tap lever 26 is turned off Fig V Drain and replace the engine oil Clean the generator with a damp soft cloth with mild detergent Do not clean the generator with water Check all nuts bolts and fasteners Ensure they are tightened if needed before storage To ensure the engine is operating correctly the spark plug must be properly gapped and free o...

Page 18: ...and engine wear It is recommended the air filter 21 is cleaned every 50 hours every 10 hours under dusty conditions ALWAYS keep the filter clean at all times WARNING Ensure the engine is switched off while undertaking this task 1 Remove the air filter cover 20 on the side of the generator using the supplied 10mm tube spanner 30 by removing unscrewing the two screws on the face of the cover in an a...

Page 19: ... 26 turned on ensure there are no leaks where the fuel hose is fitted to the outlet of the tap Maintenance Cleaning Warranty AK AJ AL LOOSEN TIGHTEN 1 Keep your machine clean The outside of the machine can be cleaned using a damp soft cloth with a mild detergent if required Never use water to clean the generator as it may cause damage to internal parts 2 Some maintenance products and solvents may ...

Page 20: ...y of your receipt to one of our National Service Agents for repair or call us 1800 909 909 for advice A listing of our Service Agents is included with your product however you can also find our most updated listing on our website www powertoolsupport com by clicking on the Service Agent link Warranty Service Service Environmental protection What your 3 year warranty means Service Support Troublesh...

Page 21: ...is chart please call Customer Service on 1800 909 909 Troubleshooting Specifications Trouble Possible cause Suggested remedy No electrical output 1 Faulty receptacle 1 Have service centre replace receptacle 2 Overload has been triggered red Overload light on 2 Remove all appliances Stop the generator and restart Reconnect appliances but with reduced load 3 Faulty power cord 3 Have an electrician r...

Page 22: ... products are developed to our stringent quality specifications If you are not entirely satisfied with this product please return it to your nearest ALDI store within 60 days from the date of purchase for a full refund or replacement or take advantage of our after sales support by calling the supplier s Customer Service Hotline Made in China WORKZONE Titanium is a registered trademark of ALDI Stor...

Reviews: