2. ADVANCED SETTINGS AND ADMINISTRATOR MODE
Thermographic images at the end of measurement - At the end of each measurement is saved thermo-
graphic image with the current state of the monitored object. The file format is .png file name begins with
the string ”
Image_
”.
Record with login/logout users - Includes start and end mes automa c inspec on together with the name
of the operator who inspec on launched or stopped. It is a text file named ”
User_log.txt
”.
Se ng the store record of data during the inspec on can be carried out the following elements:
Enable Table Logging
– Enable/disable saving a record of the table with the defini on of measured areas.
Sort Logs by Product
- Enable/disable sor ng logs to folder according selected product superior to folder
of days.
Enable Measurement Logging
– Enable/disable saving of record of sta s cs in measured areas.
Enable Thermo Image Logging
– Enable/disable saving thermal images at the end of measurement.
Enable Radiometric Image Logging
– Enable/disable saving radiometric images at the end of measurement.
Enable Duplicate Logging
– Enable/disable storage of all data records during the inspec on to duplicate
paths (e.g. a portable flash drive).
Enable Cyclic Logging
– Enable/disable saving of record of sta s cs in measured areas in each frame only
for any number of hours specified in the field on the right, the older data overgreasing newer. This se ng is
only possible to adjust the measurement Nontrigger Evalua on. These records are saved directly to a folder
”
C:\Users\User\Dokumenty\Workswell_ThermoInspector\Logs\
” to a file
Cyclic_Log.csv
.
Enable Logging Video during X s
– Enable/disable logging nonradiometric video for a specified number of
seconds before and a er the alarm, this se ng is only allowed in nontrigger mode.
Enable Logging Radiometric Video during X s
- Enable/disable logging radiometric video for a specified
number of seconds before and a er the alarm, this se ng is only allowed in nontrigger mode.
Enable Duplicate Logging
– Displays duplicate path where the records are stored data during inspec on (if
checked se ngs Enable Duplicate Logging).
2.3 Tab Analysis Mode
Figure 2.15 – Tab Analysis Mode
E-mail and Web
[email protected]
www.workswell.eu
Mobile:
+420 725 877 063
ID:
Reg. No.: 29048575
VAT No.: CZ29048575
Headquarters
Libocka 653/51b
Prague, Czech Republic
Revision 2.6 EN, 14
th
Feb, 2019
All pictures are only for illustra on.
Real values may vary.
26