31
Working with the main menu
Sense ll – 6 720 812 775 (2014/10)
The following table shows you how to set up a holiday program, interrupt a holiday program that is active and delete a holiday
program. The holiday program starts on the set date only in heating circuits in which automatic mode is active.
Heating
Control of the room temperature for the
selected heating circuits during the holiday
period:
•
With
As Saturday
, the heating system
runs in the selected heating circuits
every day in accordance with the time
program that is active for Saturday
(holiday at home).
•
A
Constant temperature
can be
selected and will be valid for the entire
holiday period for the selected heating
circuits.
•
The
Off
setting deactivates the heating
system completely for the selected
heating circuits.
•
With the
Setback
setting, the heating
system runs in the selected heating
circuits in the operating mode set by the
Installer in each case (
Reduced mode
,
Outside temperature threshold
,
Room
temperature threshold
starting on
DHW
DHW settings for the selected DHW systems
during the holiday period.
•
If
Off
is set, no DHW at all will be
available during the holiday period.
•
If
Off + therm. disinfection on
is set,
DHW heating is deactivated but thermal
disinfection is still carried out as normal
either once a week or one a day.
Note: If the holiday is spent at home, so that
DHW remains available, the DHW systems
must not be selected under
Selection heat.
circ./DHW
.
Delete
Delete all settings for the selected holiday
program
Menu item
description
Table 28 Settings for holiday programs