Appliance information
Greenstar i System
ErP
- 6 720 806 945 (2015/07)
11
LPG appliances
The following product data satisfy the requirements of the EU Regulations No. 811/2013 and No. 812/2013 supplementing Directive 2010/30/EU.
Product data
Symbol
Unit
7733600033 7733600034 7733600035 7733600036 7733600037 7733600038
Product type
–
–
9i System
ErP
LPG
12i System
ErP
LPG
15i System
ErP
LPG
18i System
ErP
LPG
21i System
ErP
LPG
24i System
ErP
LPG
Condensing boiler
–
–
Yes
Yes
Yes
Yes
Yes
Yes
Low temperature boiler
–
–
No
No
No
No
No
No
B1 boiler
–
–
No
No
No
No
No
No
Cogeneration space heater
(CHP)
–
–
No
No
No
No
No
No
Combination heater
–
–
No
No
No
No
No
No
Rated heat output
P
rated
kW
9
12
15
18
21
24
Seasonal space heating
energy efficiency
s
%
93
94
94
94
94
94
Energy efficiency class
–
–
A
A
A
A
A
A
Useful heat output
At rated heat output and
high temperature regime
1)
1) High temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
P
4
kW
9
12
15
18
21
24
At 30 % of rated heat output
and low temperature
regime
2)
2) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater inlet).
P
1
kW
3
4.1
5.1
6.2
7.2
8.2
Useful efficiency
At rated heat output and
high temperature regime
1)
4
%
88.2
88.2
87.9
87.9
87.7
87.7
At 30 % of rated heat output
and low temperature
regime
2)
1
%
99.5
99.5
99.3
99.3
99.4
99.4
Auxiliary electricity consumption
At full load
el
max
kW
0.025
0.039
0.034
0.049
0.032
0.039
At part load
el
min
kW
0.018
0.018
0.015
0.015
0.015
0.015
In standby mode
P
SB
kW
0.002
0.002
0.002
0.002
0.002
0.002
Other items
Standby heat loss
P
stby
kW
0.058
0.058
0.058
0.058
0.058
0.058
Ignition burner power
consumption
P
ign
kW
0
0
0
0
0
0
Emissions of nitrogen
oxides
NOx
mg/kWh
32
41
38
45
44
44
Sound power level, indoors
L
WA
dB(A)
49
52
50
52
49
50
Table 7 Product data for energy efficiency in accordance with Regulation (EU) no. 813/2013