Energy saving

Greenstar Danesmoor External 

ErP 

& External System 

ErP

 – 6 720 813 726 (2014/09)

9

Energy saving

9.1

Tips on energy saving

Room thermostats

Reducing the setting of the room thermostat by 1°C can reduce 
fuel consumption by up to 10%.

New control systems

Upgrade your heating control system with the latest equipment 
available. The minimum level of control for a heating system is 
a programmer, interlocking room thermostat and thermostatic 
radiator valves.

Radiators

More often than not radiators will be sited underneath a 
window, so the warm air from the radiator heats the colder 
incoming air from the window.

The performance of the radiator will be affected if the curtains 
are allowed to drape over the radiator or shelves are fitted 
above it.

The positioning of furniture and tables in front of the radiator 
should also be avoided.

It is advisable to manually adjust all radiator valves every 2-3 
months to prevent them from sticking. It is also important that 
the plastic tops of all valves are always in position and not 
cracked or damaged to help prevent accidents. Care should be 
taken when vacuum cleaning carpets to avoid damage to valves 
and pipework.

The heating system and the outputs of the radiators have been 
carefully selected by your installer. The temperature 
obtainable in any given room is dependent on all radiators 
being operated at the same time. If you decide to turn off 
radiators in unused rooms, spare bedrooms etc., you may 
experience slightly lower room temperatures in rooms adjacent 
to unheated rooms.

Heating economically

The boiler is designed to provide a high level of comfort while 
keeping oil consumption and the resulting environmental effect 
as low as possible.

The central heating control on the boiler should be set as low as 
possible while still maintaining a comfortable room 
temperature.

The temperature of each room can be set individually using the 
thermostatic radiator valves (except the primary room with the 
room thermostat).

Roof insulation

Around 30% of the heat loss from a property is through the 
roof. Replace any old insulation with new insulation, preferably 
to a minimum thickness of 200mm.

Window frames

Single glazed windows, particularly those with steel frames, 
can lose a great deal of heat.

Consideration should be given to replacement with uPVC or 
wooden framed double glazed units.

Curtains

Lined curtains, or heavier full length curtains can provide 
excellent insulation. However, always ensure that the curtains 
do not drape over radiators.

Draughts

Try to ensure that draughts around doors, windows, 
letterboxes and keyholes etc., are reduced by using a suitable 
draught excluder.

Summary of Contents for External System ErP 12/18

Page 1: ...flue and room sealed flue Greenstar Danesmoor External Regular ErP and External System ErP 12 18 18 25 25 32 6720809792 00 1Wo For fully pumped open vent and sealed central heating systems and domestic hot water cylinders For use with Kerosene Class C2 only 6 720 813 726 2014 09 ...

Page 2: ...al quality and proven reliability The Greenstar range in particular is extremely energy efficient offeringyoueconomicalrunningcostsandvalueformoney Itis amongst the top energy rated appliances available Thereisalsothereassuranceofourpartsandlabourguarantee backed up by Worcester Total Cover an optional complete maintenance scheme to keep your appliance operating at peak condition and efficiency Co...

Page 3: ...nce A sequence of defined actions or steps carried out in order to complete a task Action Next action etc A reference to a related part in the document or to other related documents To refer the reader to a specific figure table section within the manual e g figure 1 A reference number to identify or refer to a part or item In a related figure items or parts identified by a sequential number List ...

Page 4: ...ivensupervision orinstruction concerningtheuseof the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Intended use Thisappliancemustonlybeusedasaheatapplianceinasealed hot water heating system for domestic purposes Any misuse or unauthorised modifications to the app...

Page 5: ...System boiler only 6 Boiler mode indicator 7 Mode switch 8 Reset button Heating behind the front panel 9 Reset button Flue thermostat behind the front panel 10 Lockout indicator reset button located behind the front panel on the burner control box see reset button locations below flue reset boiler reset on service 3 1 4 6 5 6720809792 01 1Wo 2 6720809792 02 1Wo 1 2 7 ...

Page 6: ...ature The demand light will illuminate until the water reaches the set temperature Once the set temperature is reached the demand light extinguishes Turn the control anti clockwise to reduce the water temperature The minimum and maximum ranges of the temperature control positions are approximately 55 C to 81 C 3 2 3 Controlling the central heating Set the programmer timer to the correct time with ...

Page 7: ...r your boiler Maintenance tips Regularly check the oil level in the tank Do not obstruct the flue outlet or the air inlet Regularly check the system pressure gauge see chapter 4 Use in hard water areas In exceptionally hard water areas a device to prevent scale formation may be fitted Installation of a scale inhibitor assemblyshouldbeinaccordancewiththerequirementsofthe local water company An isol...

Page 8: ... Once the external filling loop has been located follow the instructions for re pressurising the system 1 Unscrew blanking cap 2 Attach the hose to the valves screw on hand tight 3 Turn the handle screwdriver slot through 90 to open the valves 4 The handle screwdriver slot will be in line with the valves Fig 1 External filling loop 5 When the pressure reaches between the 1 and 1 5 bar marks zone A...

Page 9: ...toensurethat condensate does not enter the primary heat exchanger The cabinet is not load bearing and only provides weather protection for the boiler inside There must be sufficient hard standing and access around the boiler for servicing WARNING Externalequipmentoperatingat230Volts must not be serviced or repaired during adverse weather conditions Do not use pressure washers or steam cleaners on ...

Page 10: ...he boiler and system Use ofincompatible additives can cause damage andwillinvalidate the boiler guarantee Condensate drain This is a condensing boiler and the terminal will at times give out a plume of water vapour This is quite normal The boiler also produces quantities of condensate which is discharged regularly via a pipe to drain This pipe must not be blocked or altered in any way Clearances s...

Page 11: ...s on room thermostat Air trapped in heating system System model Bleed radiators and re pressurise the heating system Low system water pressure System model Re pressurise the system refer to page 8 Desired room temperature is too high Thermostatic radiator valve s are set too high Turn down thermostatic radiator valves room thermostat Room thermostat is set too high Reduce central heating temperatu...

Page 12: ... not attempt further resets Contact your Service Engineer for advice 4 Boiler mode light ON lockout light OFF Boiler not on No heating hot water Press Reset Button B press Reset Button C both are below the fascia If the boiler remains off contact your Service Engineer for advice If this fault re occurs contact your Installer or Service Engineer 5 Both lights OFF Boiler not on No heating hot water ...

Page 13: ...g points before calling for a service engineer 1 Oil level in the tank 2 Power to the boiler 3 All control settings Technical support In the event of a appliance fault or breakdown please contact Worcester Bosch Group appointments team on 0330 123 9339 Your advisor will arrange for an engineer to call with the minimum of delay under normal circumstances this will be from 1 3 working days excluding...

Page 14: ...radiators have been carefully selected by your installer The temperature obtainable in any given room is dependent on all radiators being operated at the same time If you decide to turn off radiators in unused rooms spare bedrooms etc you may experienceslightlylowerroomtemperaturesinroomsadjacent to unheated rooms Heating economically The boiler is designed to provide a high level of comfort while...

Page 15: ...aulty material or manufacturer subject to Terms and Conditions To read the full Terms Conditions please visit us on line at www worcester bosch co uk guarantee The Guarantee Registration form is available on this same page and can be completed and submitted electronically Alternatively please telephone one of our Guarantee Registration advisors on 0330 123 2552 Your statutory rights are not affect...

Page 16: ...9 SPARES 0330 123 9779 LITERATURE 0330 123 9119 TRAINING 0330 123 0166 SALES 0330 123 9669 Worcester Bosch Group Cotswold Way Warndon Worcester WR4 9SW Tel 0330 123 9559 Worcester Bosch Group is a brand name of Bosch Thermotechnology Ltd worcester bosch co uk 6 720 813 726 2014 09 ...

Reviews: