11.7 Install the Boiler
Check that the gas and water valves are closed. Refer to Fig 13.
Fit the fibre washers, in the hardware pack, to the service valves
on the manifold.
Remove the two fixing screws.
Lift the appliance to the wall, engage in the top support and
lower onto the manifold assembly. Tighten the gas and water
connections.
Unscrew the facia fixing screws. Refer to Fig 18.
Unhook the panel and lower it into the bottom support lugs. Do
not strain the support strap. Refer to Fig. 18 and 41.
Fix the boiler at the right and left to the mounting frame using
the two lower fixing screws provided. Refer to Fig. 13 and 16.
Remove the protective cap from the flexible hose.
Check that the O-ring is in good condition.
Connect the hose to the system connection point-
HAND TIGHTEN ONLY.
Refer to Figs 12 & 17.
Fit a discharge pipe to the relief valve leading it
away from any electrics or where it might be a hazard. The pipe
must not be less than 15mm in diameter and must run
continuously downward outside the appliance. Refer to Fig. 17.
14
65
65
65
65
CH
Flow
DHW
Flow
Gas
DHW
Cold
Inlet
CH
Return
Fibre
Washer
Fig. 13 . Manifold assembly
All dimensions in mm
Fig. 14 . Facia cover
1
1. Cabinet
2. Control
3. Facia cover
4. Facia cover clips (4)
5. Cabinet fixing screws (2)
2
3
4
Fig. 15 . Appliance location
1. Casing location bracket
2. Appliance location bracket
3. Wall mounting frame
4. Pipe channel
2
1
4
5
*
*
Filling loop not shown
Fig. 16 . Appliance fixing
3
1
2
1. Appliance fixing bracket
2. Fixing screw
!
IMPORTANT
Lower fixing
screws (2)