SETTINGS
6 720 802 172 (2012/06)
17
Room temperature
:
▶ Set the room temperature that should apply in the event of enabled
external control.
▶ Value > 0 °C enables the function.
The highest temperature is used if temperature changes have been set
for a certain circuit at several external inputs.
Other functions:
13.8 GENERAL
Among other things, settings for date and time are available here.
> Room sensor settings
(room controller)
>> Show outdoor temperature in room sensor
(room controller)
>
Set date
>
Set time
▶ Check and change, if necessary, date and time. These are used by the
control unit to manage the different clock settings, e.g., holiday and
room temperature program.
>
Summer/winter time
▶ Select if there should be automatic change over between summer and
winter time or not (dates according to EU standard).
>
Display contrast
▶ If necessary, change the background light of the control panel.
>
Language
▶ Change language, if desired.
13.9 ALARMS
The different alarms that can occur are described in (
Chapter 14).
Under
Alarms
there is:
•
Information log
•
Delete information log
•
Alarm log
•
Delete alarm log
•
Alarm indication
>
Information log
The information log shows information from the heat pump. The
information log symbol is displayed in the control panel initial menu
when there is active information.
>
Delete information log
The information log is deleted here.
>
Alarm log
The alarm log shows the alarms and warnings that have occurred. Alarm
category (
Chapter 14.5) is displayed in the top left corner of the
display. If the alarm is active, the alarm symbol (
Chapter 11.3) is
displayed both in the alarm log and the initial menu of the control panel.
>
Delete alarm log
The alarm log is deleted here.
>
Alarm indication
Settings for alarm buzzer and status lamp are made here.
>>
Alarm buzzer signal
>>>
Interval
▶ Set the length of the alarm interval.
The alarm buzzer sounds for one second and is silent during the rest
of the interval. The setting applies to all alarm buzzers.
>>>
Blocking time
▶ Set the times between which alarms buzzers should not be allowed to
produce an acoustic signal.
>>
Alarm indication control unit
>>>
Block alarm buzzer
The setting applies only to the control unit's alarm buzzer.
>>
Alarm indication room sensor
(room controller)
>>>
Block alarm indicator lamp
The setting applies to all room controllers.
Factory setting
No (0.0 °C)
Lowest value
10.0 °C
Highest value
35.0 °C
Table 33 Room temperature
Factory setting
No
Alternative
Yes/No
Table 34 Functions
Factory setting
No
Alternative
Yes/No
Table 35 Show outdoor temperature in room controller
Factory setting
Format
yyyy-mm-dd
Table 36 Date
Factory setting
Format
hh:mm:ss
Table 37 Time
Factory setting
Automatic
Alternative
Manual/Automatic
Table 38 Summer/winter time.
Factory setting
70%
Lowest value
0%
Highest value
100%
Table 39 Display contrast
Factory setting
2s
Lowest value
2s
Highest value
3600s (60min)
Table 40 Interval
Factory setting
Off
Start time
0:00 - 23:45
Stop time
0:00 - 23:45
Table 41 Blocking time
Factory setting
No
Alternative
No/Yes
Table 42 Block alarm buzzer
Factory setting
Yes
Alternative
No/Yes
Table 43 Block indicator lamp