WOONGINCOWAY CO. LTD.
Environmental
Technology Laboratory
CAIRS
Air Cleaner
AP-1004AH
43
[Step4] Separates main PCB related cable
connectors.
[Step5] Remove 2 main PCB bolts and then
separates main PCB. Reverse order is applied
when reassembling.
[Step6] Separates 2 key PCB related cable
connectors from PCB.
[Step7] Remove 3 bolts on left side of fan guide
and 1 on external side.
[Step8] Remove key PCB from filter guide.
Reverse order is applied when reassembling.