WOONGINCOWAY CO. LTD.
Environmental
Technology Laboratory
CAIRS
Air Cleaner
AP-1004AH
26
3. System Operation Fundamental
3-1 Product Operation Specification
1. Applied Scope
The specification of this document is written for electric control unit (hereunder
called
“
PCB
”
) applied to newly developed products of customized air cleaner
(ACE) of WOONGINCOWAY CO. LTD..
2. Condition
1) Power : AC 220V ± 15%, 60Hz
2) Temperature : - 20℃ ~ + 70℃ : keeping
- 10℃ ~ + 50℃ : use
3) Humidity : within 30%~90%RH (only if any dew does not exist)
4) Timer : Continuous operation
3. Power Part
1) Standard Power : AC220V ±15%, 50/60Hz
2) Power S.M.P.S. : SANKEN ( STR-A6351)
: Wide type (AC90V ~ AC260V)
3) Power FUSE : 250V, 3A Fast acting 삼주리틀 Fuse
4. Major Parts Description
4.1 Input Part
1) CDS Sensor : decides whether to start sleeping mode by sensing brightness
or light
- HEIMANN company, model name : A90.12
2) Dust Sensor : display pollution level by detecting dust (particle) and wind
volume
- Model name : PPD3 (SHINYOUNG) , Regularity : DC 5V/90mA,
3) Motor rotate speed Hall sensor signal : DC 15V(PWM Control Print)