WOONGINCOWAY CO. LTD.
Environmental
Technology Laboratory
CAIRS
Air Cleaner
AP-1004AH
46
■
Negative Ion Fin Case and Fin/Fan Change
[Step1] Remove front cover, filter case, base, and
rear cover from product.
[Step2] Remove 4 fan guide bolts and related
cable connectors and separates fan guide.
[Step3] After turning over fan guide, remove 2
bolts related to negative ion fin case to separate
fin case.
[Step4] If removing negative ion fin case, negative
ion fan is connected to fan guide and negative ion
fin is connected to fin case. Remove cables
connected to fin/fan and then separates fin/fan by
removing 2 bolts. Reverse order is applied when
reassembling.
※ When separating fin/fan, use things
like a gimlet for easy separation.