Installation and Operation 

Woodway Engineering Ltd 

  OPTINS-4.0 Rev 4 

Page 5 of 9 

December 2007 

 

Keypad Programming 

WARNING! Keypad programming should only be carried out with either the 
data wire to the receiver disconnected or the receiver output connector 
removed to prevent un-intentional operation of the vehicle equipment.

 

Changes to the keypad settings should not be carried out with the vehicle engine 
running

Keypad Lockout 

In normal use the keypad is locked to prevent changes to the keypad function. Keypad 
functions cannot be changed until the lock is disabled. To disable the lock press and hold 
switches 1, 4, 7, 12 and 14 until a beep is heard. The led at the top of the panel will be 
permanently on. To enable the lock press and hold SW13 and SW14 until a beep is 
heard. The keypad will de-activate. To re-activate press any key. 

To program P1: 

Press and hold down P1 until the confirmation beep is heard (5 seconds approx). 
P1 will flash and the current program setting, if any, will be activated. All 
programmed switches will be illuminated. 

Select the new combination of buttons to activate with P1 by activating/de-

activating buttons 1 to 13, leaving only those buttons required illuminated. 

When the selection is complete, do not press any other button until the beep is heard to confirm the programme. 
(Approximately 10 seconds from the last selection). P1 will stop flashing when programmed. 

Reset the keypad by pressing the Reset button. 

To program P2, repeat as for P1. 

Switch self-cancelling mode: 

In some situations it may be preferable to have buttons self-cancelling, i.e. if one button in the row is active pressing 
another one in the same row will cancel it. This is possible for individual rows of buttons, i.e. 

1 - 3

4 - 6

7 – 9, 10 -12

 and 

a self cancelling bank 

7 – 12 

To program the buttons for self-cancelling mode: 

Press and hold down the first button on the row, i.e.1, 4, 7 or 10 and, at the same time, press and hold down SW14 until a 
beep is heard. Repeat this procedure for further row settings.  

Buttons 

7

 to 

12

 may be a self-cancelling bank. To set this option, press the 

Reset Button

 and button 

12

To cancel the self-cancelling mode, repeat the above procedures. 

To program the buttons for momentary or latching operation: 

The default setting for switches 1-12 is latching. To change any switch from latching to momentary operation or vice-
versa; 

1  Press and hold down SW13 and the switch to be changed for 5 secs until a confirmation beep is heard 

2  Release both switches and press SW14. 

Special Strobe Setting: 

The special strobe setting is only applicable to switches 1 to 3 and is usually set when the system is used to control ‘360’ 
light selection on a Woodway lightbar. When this option is set pressing SW1 will also activate SW2 and SW3. 

1  Press and hold down SW14 and switch 2 until a confirmation beep is heard. 

2  Release both switches. 

3  To cancel the setting, repeat the procedure. 

External 999 Input 

To enable this function. 

1  Press and hold SW6 and SW14 until a beep is heard. 

To cancel the setting, press SW3 and SW14 until a beep is heard 

Summary of Contents for Opti-Link

Page 1: ...INSTALLATION OPERATION Opti Link ENGINEERS FOR THE EMERGENCY WARNING INDUSTRY ...

Page 2: ...ights Reserved Important Installation and Safety Notes Modules and connectors are not waterproof Install modules and cables in a dry location away from excessive heat humidity and any components likely to damage the system It is the installer s responsibility to ensure that the method of installation does not damage or interfere with vehicle equipment and wiring if the vehicle is fitted with airba...

Page 3: ...RRIVAL SWITCHING 4 EXTERNAL 999 SWITCHING 4 PA MICROPHONE 4 MOUNTING 4 DEFAULT PROGRAMME 4 KEYPAD PROGRAMMING 5 KEYPAD LOCKOUT 5 TO PROGRAM P1 5 SWITCH SELF CANCELLING MODE 5 TO PROGRAM THE BUTTONS FOR SELF CANCELLING MODE 5 TO PROGRAM THE BUTTONS FOR MOMENTARY OR LATCHING OPERATION 5 SPECIAL STROBE SETTING 5 EXTERNAL 999 INPUT 5 CHANGING AND FITTING THE SWITCH LEGENDS 6 TO FIT THE SWITCH LEGENDS ...

Page 4: ...er Module Fig 3 The Output Receiver Module decodes the data and activates the required outputs via a 14 way connector note that position 14 on this connector is not used A green Data OK led flashes to indicate that the data link is functioning The switch outputs from the Output Receiver Module interface directly with the low current control wiring of Woodway supplied light bars sirens and strobe p...

Page 5: ...progress When the test is complete the keypad will automatically reset Sleep Wake Up Function The system will automatically shut down sleep after approximately 1 hour if no channels are active and the supply voltage is less than 13 5V i e the vehicle is not running The system will wake up when a switch is pressed the voltage exceeds 13 5V or the door is opened if connected The system will not go t...

Page 6: ...ad by pressing the Reset button 5 To program P2 repeat as for P1 Switch self cancelling mode In some situations it may be preferable to have buttons self cancelling i e if one button in the row is active pressing another one in the same row will cancel it This is possible for individual rows of buttons i e 1 3 4 6 7 9 10 12 and a self cancelling bank 7 12 To program the buttons for self cancelling...

Page 7: ...he blade around the edge to prise the bezel completely away from the keypad 5 Each switch button is made up of three parts the button pad the legend and the lens Remove the button to be changed and slide the button lens left or right to remove it from the button assembly 6 Fit the new legend in the correct orientation and slide the lens back onto the button 7 Replace all the button assemblies onto...

Page 8: ...set too high Turn the pot anti clockwise to reduce the volume See Fig 2 Keypad and speaker too close together Increase the physical separation between the keypad and the speaker The Keypad led is flashing Low Voltage Check that the voltage is healthy For 12V systems 9 5V The keypad led is permanently on and the system is not functioning Internal eprom fault Replace keypad One or more switches will...

Page 9: ...Opti Link WOODWAY Installation and Operation Woodway Engineering Ltd OPTINS 4 0 Rev 4 Page 8 of 9 December 2007 Opti Link System Installation Wiring Diagrams System Wiring ...

Page 10: ...White Orange Hands Free Socket SK4 Pin Wire Colour Function 1 White Blue Mic 2 White Black Mic 3 4 White Violet PTT Plug P2 Pin Wire Colour Function 1 Red White Not Used 2 White Green Horn Ring 3 White Brown Wail 4 White Red Yelp 5 White Orange Hands Free 6 White Yellow Not Used 7 White Violet PTT 8 White Black Mic 9 White Blue Mic Figure 4 Output Receiver Relay Connections Figure 4a Auxiliary Equ...

Reviews: