19 | UM-BS-EN-A3
3
Technical Data
3.1
Technical Specifications
Parameters
Description
Overall Dimensions
44
” W x 7
5
” L x 64” H
(112 x 191 x 163 cm)
Running/Walking Surface
22” W x 68” L (55 x 173
cm)
Weight
445 lbs. (201 kg)
Technology
Hardness / Lateral Play
60 slats (replaceable), rubber on aluminum T-sections
40 Shore A / 4 mm lateral tolerance
Drive System
114 ball bearings, 12 roller guides
Max. User Weight
Running/Walking: 400 lbs. (180 kg)
Conditions for Use (operation)
Temperature: 50°F to 95°F (+10°C to +35°C)
Relative humidity: 20 -95% (not condensed)
Air pressure: 700 - 1060hPa
Enclosure Rating: IP2x
Power Connection
Grounded plug
Rated voltage: 115/120 VAC or 208/220 VAC
Rated current: 8 A or 4A respectively, 50/60 Hz
Cord length: 6.5 ft. (2 m)
Classification**
Safety class I device, type B applied part
Enclosure rating: IP2X
Rated for continuous operation.
Applied Parts (Type B)
Boost Display
Boost Shorts
Height Adjustment Kart
Height Adjustment Latch
*
For performance tests, intense intervals, or sprint training, runner's additional safety measures must be provided. In this case WOODWAY
strongly recommends the use of the all protection option with chest strap and emergency stop function to minimize the risk of injury.
**
Classification according to EN 60601-1
3.2
Conditions for Use
Description
Parameters
Ambient Temperature 50°F to 104°F (10°C to 40°C)
Relative Humidity
20-95% (not condensed)
Air Pressure
700-1060 hPa
Enclosure Rating
IP2x