To Reposition (or Remove) Movable Pad Mounts 

1)  Remove the cotterless hitch pin from one movable pad mount by 

pulling on the pull ring. 

2)  Move the pad mount to the desired position on the pad frame and 

align the holes for the cotterless hitch pin in the pad mount with 
the corresponding holes in the pad frame. 

3)  Secure the pad mount by pushing the cotterless hitch pin through 

the holes until the retaining ball emerges on the far side of the pad mount. 

4)  Make sure that the vacuum hose connecting the vacuum pad to the vacuum system is not 

pinched, kinked, cut or abraded and that it will not interfere with lifter operations. 

5)  Repeat steps #1-4 to position other pad mounts as needed.  Always position vacuum pads in 

a symmetrical arrangement, and make sure that all vacuum hoses are functioning correctly. 

To remove a vacuum pad from the pad frame all together, disconnect the corresponding vacuum 
hose and remove the pad mount as directed above.  Make sure to store the pad and its mount in 

a clean, dry location to protect them from environmental exposure. 

To Install/Remove Extension Arms 

1)  Remove the cotterless hitch pin (see illustration above) from one extension arm by pulling on 

the pull ring. 

2)  Insert the end of the extension arm in its socket on the pad frame, so that the holes align for 

the cotterless hitch pin. 

3)  Secure the extension arm in the pad frame by pushing the cotterless hitch pin through the 

holes until the retaining ball emerges on the far side of the pad frame socket. 

4)  Remove the end of the quick connector from the spring clip on the extension arm, and 

connect the vacuum hose as directed above. 

5)  Repeat steps #1-4 to install other extension arms as needed for the pad frame configuration 

desired. 

6)  To remove extension arms, reverse this procedure.  Store removed extension arms in a clean, 

dry location to protect them from environmental exposure. 

About Secondary Rotation Stops 

The lifter features two sets of holes in the rotation wear plate, which function as stops for the 

rotation latch.  Rotation stops allow the operator to secure the load at each quarter turn of the 
rotation, keeping the long dimensions of an upright load either parallel or perpendicular to the 

ground.  The secondary stops are rotated approximately 30° from the primary stops, to provide 

the same load positioning when the pad frame is in a linear configuration (see illustration). 
Note:  When you are assembling a linear configuration, be sure to install extension arms in the 

two sockets as shown in the illustration, since the secondary rotation stops do not align correctly 

when the arms are placed in the other two sockets. 

COTTERLESS HITCH PIN

 

1  PULL RING 

2  RETAINING BALL 

Summary of Contents for MRTA611LDC

Page 1: ...AL NUMBER __________ QUADRA TILT ROTATOR DC VOLTAGE WITH DUAL VACUUM SYSTEM READ ALL INSTRUCTIONS AND WARNINGS BEFORE OPERATING THIS LIFTER DESIGNED FOR THE MATERIALS HANDLING PROFESSIONAL P O Box 368...

Page 2: ...ng Temperatures 15 to 105 F 9 to 40 C Service Life This lifter is designed to have a service life of at least 20 000 lifting cycles when used as intended Wiring Diagram The following wiring diagram is...

Page 3: ...d Capacity or attempt to lift loads the lifter is not designed for see INTENDED USE LOAD CHARACTERISTICS Never attempt to lift cracked or broken glass with this lifter Always position the vacuum pads...

Page 4: ...nce in each section Standard MRTA611LDC shown 1 LIFT SPOOL 8 AIR FILTER 15 VACUUM PUMP 2 LIFT BAR 9 LOW VACUUM WARNING LIGHT 16 VACUUM PAD 3 BATTERY 10 VALVE HANDLE with MOVABLE MOUNT 4 BATTERY GAUGE...

Page 5: ...with restraining latch to prevent lift spool from slipping off under any circumstances If the lifter is equipped with optional tilt locks make sure they are disengaged see OPERATION TO LIFT AND MOVE T...

Page 6: ...ame configurations to accommodate different load dimensions and weights see SPECIFICATIONS Pad Spread and Load Capacity The following illustration shows several possible configurations Select a config...

Page 7: ...o calculate the load capacity when some vacuum pads are removed consult the Per Pad Load Capacity see SPECIFICATIONS and multiply by the number of pads currently in use Make sure all vacuum hoses are...

Page 8: ...end of the extension arm in its socket on the pad frame so that the holes align for the cotterless hitch pin 3 Secure the extension arm in the pad frame by pushing the cotterless hitch pin through th...

Page 9: ...he vacuum pads without breaking or otherwise being damaged The allowable overhang depends on the kind of load material being lifted the thickness of the material and the angle at which it is handled i...

Page 10: ...owing restrictions WARNING Never use lifter in dangerous environments This lifter is not intended for use in any environment that is inherently dangerous to the operator or likely to compromise the li...

Page 11: ...k battery energy before using lifter See MAINTENANCE BATTERY TEST Perform all inspections and tests required by the INSPECTION and TESTING SCHEDULES see MAINTENANCE In addition if the lifter has been...

Page 12: ...aximum load weight see TO LIFT AND MOVE THE LOAD Load Capacity and the Warning Light to follow The valve handle must remain in the APPLY position throughout the entire lift WARNING Keep valve handle i...

Page 13: ...t a test to determine whether the lifter is designed to lift the load as follows 1 Make sure the lifter s vacuum generating system is functioning correctly see MAINTENANCE VACUUM TEST 2 Apply the vacu...

Page 14: ...loads or other causes of incidental loading Tilt locks are intended as a secondary safety device and do not eliminate the need to center the load correctly on the pad frame see TO APPLY THE PADS TO A...

Page 15: ...T see MAINTENANCE and inspect the vacuum pads for damage see MAINTENANCE VACUUM PAD MAINTENANCE Inspection If the vacuum loss cannot be remedied immediately perform inspection and maintenance as neede...

Page 16: ...Remember that the load requires more vertical space when tilted to the upright position as well as more horizontal space when tilted to the flat position Make sure there is sufficient clearance for th...

Page 17: ...cuum pads and all other components from damage while in transit Storing the Lifter Use the covers supplied to keep the vacuum pads clean In accordance with CE Standard EN 13155 the lifter is designed...

Page 18: ...er s structure for visual damage Examine the vacuum system including vacuum pads fittings and hoses for visual damage Examine the air filter for conditions requiring service see AIR FILTER MAINTENANCE...

Page 19: ...h the vacuum generating system Note After the test is completed move the valve handle to the RELEASE position power off before reconnecting the battery 4 Raise the load a minimal distance to assure th...

Page 20: ...ate an energy level that is higher than actual due to a surface charge on the battery After the pump runs for approximately one minute the surface charge dissipates allowing the operator to take an ac...

Page 21: ...urface contamination must be thoroughly cleaned see Cleaning discussion to follow Over time the rubber in a pad may experience hardening or leaching of chemicals resulting in stiffness or surface glaz...

Page 22: ...ean the face of each vacuum pad as previously directed see VACUUM PAD MAINTENANCE Cleaning 2 Apply the lifter to a clean smooth nonporous surface The surface should be flat or possess no more curvatur...

Page 23: ...amaged Note Do not attempt to remove the snap ring on the bowl 2 Remove any liquid or other contaminants in the bowl and determine whether the filter screen needs further attention see Conditions Requ...

Page 24: ...5 1 Remove the four head screws 1 and remove the head 2 2 Turn the head upside down and remove the four valve plate screws 9 3 Lift out the valve plate 6 to access the exhaust valve flapper and head g...

Page 25: ...pped with the Dual Vacuum System have 2 vacuum switches Directions are the same for these lifters except that each vacuum switch must be tested and adjusted individually When you are evaluating vacuum...

Page 26: ...um level turn the screw counter clockwise when viewing vacuum switch from end with electrical connectors 2 Recheck the vacuum switch setting following each 1 6th turn of the adjustment screw In order...

Page 27: ...light 1 64236 Vacuum Switch 1 4 NPT 2 64230 Roller Lever Switch 1 64200 Push Button Switch for battery test button 1 59080 Vacuum Control Valve w Handle for Dual Vacuum System 1 59028 Movable Pad Mou...

Page 28: ...d during use Repairs are required due to abnormal wear and tear The product has been damaged misused or neglected If a problem is not covered under warranty Powr Grip will notify the customer of costs...

Page 29: ...t exceed 88 dBa under any circumstances Furthermore if ambient noise measures 88 dBa the alarm volume must be set to maximum and the operator must remain within 2 60 cm of the warning buzzer in order...

Page 30: ...larm may sound in such circumstances consult the OPERATION section of the main instructions see TO APPLY THE PADS TO A LOAD Vacuum Level on Other Surfaces to determine whether the lifter can be used t...