28
L100001
29
ON
OFF
OPTIONAL REMOTE
,
WALL SWITCH
OR
PILOT
HI
LO
ON
OFF
TH
TP
TH/TP
REMOTE WALL MOUNTED SWITCH
A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a junc-
tion box at the desired location on the wall.
See Figure 35
. Do not extend beyond the wall switch wire length provided.
NOTE:
Extended lengths of wire may cause the fireplace not to function properly. Longer length of wire is permitted
if the wire is made out of larger gauge (diameter) wire. Always check with local code.
Figure 35 - Wiring Diagram for Wall Switch
ELECTRICAL INSTALLATION
ELECTRICAL WIRING
Verify proper operation after servicing.
This fireplace will work without any electrical supply. Electricity is only needed to operate blower.
NOTE: If installed in mobile home, fireplace must be bolted securely to floor.
Electrical connections should only be performed by a qualified, licensed electrician. Main
power must be off when connecting to main electrical power supply or performing service.
All wiring shall be in compliance with all local, city, and state codes. The appliance,
when installed, must be electrically grounded in accordance with local codes, or in the
absence of local codes, with the
National Electrical Code ANSI/ NFPA 70 (latest edition)
and
Canadian Electrical Code, CSA C22.1.
WARNING
Label all wires before disconnecting when
servicing controls. Wiring errors can cause
improper and dangerous operation.
CAUTION
THE WALL SWITCH OR WALL THERMOSTAT MUST BE CONNECTED
NEVER
TO ANY EXTERNAL POWER SUCH AS HOUSEHOLD 110V CIRCUIT!
DANGER!
THERMOSTAT
Summary of Contents for MONTEREY-(N
Page 31: ...LOG SET 31...
Page 32: ...Figure 41 Log set placement LOG SETT contunue 32...
Page 44: ...127 6...
Page 45: ...127 6...
Page 46: ...127 6...