7

** DO NOT Power on the water pup if there is no enough water inside the tub.

** The setting temperature range is between 86˚

F to 122

˚

F (30

˚

C – 50

˚C)

3. Operating Instruction on Control Panel

(1) 

POWER ON/OFF:

 Press and hold the power button        for 2 seconds to turn it on.  Repeat the 

same operation to turn off the power.

(2) 

CHROMO THERAPHY LIGHT ON/OFF:

 When power is on keep touching the Left and Right               

                buttons until the cursoron the LCD is on the Chromo Therapy light position       , press 

the OK         button and the light will work; repeat thesame operation to turn off the light.

(3)

 AIR BUBBLE ON/OFF: 

When power is on, keep touching the Left and Right               buttons until  

thecursor on the LCD is on the Air Bubble position       ,press the OK         button and the air 

bubble blower will start to function;repeat the same operation to turn off the Air bubble blower

(4) 

WAVE MASSAGE ON/OFF: 

When power is on, keep touching the Left and Right               

buttons until thecursor on the LCD is on the Wave Massage         position, then press OK         

button, the Wave massage will start to function and repeat the same operation to turn off the 

wave massage. (Make sure there is enough water inside the tub)

(5) 

HEATER ON/OFF:

 ONLY FUNCTION when wave massage is running. When power is on 

keeptouching the Left and Right               buttons until the cursor on the LCD is on the Thermostat  

      position and press the OK         button to turn on, repeat the same operation to turn it off.

(6) 

TEMPERATURE SETTING:

 When heater is running, press the function        button until the 

digital twinkleon display temperature on LCD display. Press the Left/Down        button to decrease 

the temperature by 1

˚C, pressthe Right/Up        button to increase the temperature by 1˚

C

Summary of Contents for BJ100

Page 1: ...mbing Code of Canada NPC AIR AND WHIRLPOOL HEATED BATHTUB BJ100 BJ400 This products must be installed by a fully insured and licensed plumber only Installation of any our product by anyone other than fully insured and licensed plumber shall void limited warranty We recommends that such licensed plumber has experience in the installation of products We are not responsible for local code compliance ...

Page 2: ...IDGE reserves the right to make changes in product characteristics packaging or availability at any time without notice IMPORTANT INFORMATION Measurements are 1 2 and subject to change without notice Specifications Configurations are subject to change without notice Please measure tub on site before installation Please note that installer s must be certified or warranty will be voided Measurements he...

Page 3: ...aration Position the plumbing according to rough in dimensions Cap the supplies and check for leaks BEFORE INSTALLING UNIT CAUTION Ensure a watertight seal on the bath drain connections A Install the faucet valving and shower head tee When drilling bathtub for faucet ensure sufficient clearance Open the hot and cold water valves and check the supply connections for leaks B Run water into the bath a...

Page 4: ...ed It is the responsibility of the installer to test run the bathtub check all the fittings for leaks and test the control functions NON OBSERVANCE WILL INVALIDATE FACTORY WARRANTY 6 The unit must be connected only to a supply circuit that is protected by a Ground Fault Circuit Interrupter GFCI Such a GFCI should be provided by the installer and should be tested on a routine basis 3 Set the bathtub...

Page 5: ...rpose Electrical Power Outlet Control box Heater 1 5KW Hydromassage Pump 0 75KW Air Blower 0 3KW BJ400 RESET 120V 15AMP Dedicated GFCI Breaker LED LIGHTS OZONE CAN SHARE A BREAKER R E S E T CGFI Outlet R WOODBRIDGE 5 10mm 02 to 0 4 Each Power cord Requires a Dedicated 120V 15AMP GFCI Breaker HEATED AIR MASSAGE TUB HEATED WHIRLPOOL TUB WHIRLPOOL AIR BATHTUB ...

Page 6: ...in control box 2 Control Panel lcons MAIN CONTROL BOX G ND L IGHT PANEL M PUMP M BLOWE R HE ATE R TO HE ATE R display window Power Function Right Up OK button Left Down Chromo Theraphy light Wave Massage Thermostate Air Bubble BJ100 ...

Page 7: ...e air bubble blower will start to function repeat the same operation to turn off the Air bubble blower 4 WAVE MASSAGE ON OFF When power is on keep touching the Left and Right buttons until thecursor on the LCD is on the Wave Massage position then press OK button the Wave massage will start to function and repeat the same operation to turn off the wave massage Make sure there is enough water inside...

Page 8: ...hermostat switch to turn on the heater repeat the same operation to turn off thermostat function 6 Under thermostat cycle long press Thermostat switch to get into water temperature setting mode When Thermostat icon blinking continue to press till desired temperature then release blinking will continue for few seconds then stop and temperature display will show current water temperature When settin...

Page 9: ... 6 Caution 1 Carefully read this user manual before you operate this unit and keep this user manual for future reference 2 Be aware of the high voltage warning labels on the unit do not touch it 3 DO NOT long time expose control panel under wet heat conditions keep it away from any high frequency equipment Clean it with dry cloth after use 4 ALWAYS keep clean water inside the tub because dirty wat...

Page 10: ...5 NOTES DATE OF INSTALL INSTALLER S NAME PLUMBER CONTRACTOR LICENSE INSTALLER INFORMATION NOTES DATE OF INSTALL INSTALLER S NAME PLUMBER CONTRACTOR LICENSE INSTALLER INFORMATION 10 ...

Page 11: ...ully insured and licensed contractor only Installation by anyoneother than fully insured and licensed contractorwillvoid this limited warranty This warranty does not cover surface damaged caused by use of chemicals that break through or dissolve the surface finish or damage caused by the accidental dropping of sharp or heavy objects Improper care and use of abrasive cleaners and will void the warra...

Page 12: ...surface shine is restored Repair and Maintenance The bathtub must be installed and used as described in this manual Use caution when entering or exiting the bathtub Do not permit children or persons with infirmities to use the bathtub without supervision of an adult People using any medications or having adverse medical history must consult a physician prior to use of the bathtub to avoid potential...