background image

12

REPLACEMENT PARTS ARE AVAILABLE THROUGH YOUR RETAILER

REPLACEMENT PARTS

Failure to position the 
parts  in  accordance 
with  these  diagrams 
or  failure  to  use  only 
parts 

specifically 

approved  with  this 
appliance  may  result 
in property damage or 
personal injury.

WARNING 

 Item  Description 

QTY 

Natural 

Propane

1      Burner Assembly

 

11 

Log #1

2            

12     Log #2 

Glass

2            

13 

Log #3 

  1            

             

FBB-N,P

14 

Log #4

1            

LOG SET (optional)

  1            M100503             M100503

 

1

            

W600001             W600002

Elbow 

1            H100036 

    H100036 

          Media (standard)             1            G100048              G100048

10 

Stones (optional) 

1            G100049  

 G100049

Burner T

 

  

 

 

 

 

 

 

y

a

r

1  

    

W600003             W600003

   6       Pressure Regulator

1            F200110              F200111 

    7 

Flex Connector 

1            

C100072              C100072

Shutoff Valve 

F200066              F200066

Orifice 

1            F200016              F200015

Reducer Bushing 

1            H100007              

    N/A

Summary of Contents for FBB-N

Page 1: ...installation adjustment alteration service or maintenance can cause injury or property damage Read the instalation ope rating and maintenance instructions thoroughly before installing or servicing thi...

Page 2: ...cal Code ANSI NFPA 70 9 Do not use appliance if any part has been under water Immediatelycall a qualified service technician to inspect the room appliance and to replaceany part of the control system...

Page 3: ...nal and safe for use Turn OFF the appliance and let it cool INSTALLATION CAUTION Do not remove the metal data plates attached to the Linear Burner System These plates contain important information NOT...

Page 4: ...FIRE PIT INSTALLATION EXAMPLES 4 Clearance to combustibles must be maintained according to Page 3 Non combustible materials only...

Page 5: ...or is installed wrong unit may not run properly CHECKING GAS CONNECTION Test Pressures in Excess Of 1 2 psi 3 5 kPa The appliance and its individual shutoff valve must be discon nected from the gas su...

Page 6: ...OUTDOOR FIRE PIT DIMENSIONS INPUT RATE BTU h GAS TYPE NATURAL PROPANE 54 000 60 000 ORIFICE SIZE BURNER PORTS 28 43 66 66 PORT SIZE 1 8 1 8 MODEL FBB N FBB P SIDE VIEW TOP VIEW 20 00 5 00 6...

Page 7: ...ntrol Valve see also Parts List 2 Place the firestarter near the burner ports on top of the burner Light the firestarter 3 For a Natural Gas Fire Pit turn on the ON OFF valve slowly at the unit For a...

Page 8: ...e any lint or foreign material with a brush or vacuum cleaner normal operation The burner must be replaced prior to the appliance being put into operation if it evident that the burner is damaged Turn...

Page 9: ...natural gas company 2 Separate the stones or logs to allow more flame passage 3 Remove any foreign items from the flame pattern and or check for proper orifice sizing 1 Relieve any tight bends or kink...

Page 10: ...10 FOR PART DESCRIPTION SEE NEXT PAGE 16 ILLUSTRATED PARTS LIST INLET WITH PRESSURE REGULATOR MANUAL SHUT OFF VALVE 5 6 7 1 2 3 4 8 PROPANE BURNER NATURAL GAS BURNER...

Page 11: ...11 FOR PART DESCRIPTION SEE NEXT PAGE 16 ILLUSTRATED PARTS LIST Continued BURNER GLASS MEDIA OPTIONAL STONES OPTIONAL LOG SET 11 13 2 PCS 2 PCS 1 PC 1 PC 12 14 9 10...

Page 12: ...Item Description QTY Natural Propane 1 Burner Assembly 11 Log 1 2 12 Log 2 Glass 2 13 Log 3 1 FBB N P 14 Log 4 1 LOG SET optional 1 M100503 M100503 1 W600001 W600002 3 Elbow 1 H100036 H100036 9 Media...

Page 13: ...127 6...

Page 14: ...127 6...

Page 15: ...127 6...

Page 16: ...g the warranty of merchanta any other obligations or liabilities in connection with sale or use of the appliance In states that do not allow limi tations on how long an implied warranty lasts or do no...