background image

ILLUSTRATED PARTS LIST

WARNING 

   

 

 

 

 

 

 

 

Failure to position the parts  in  accordance with  these

  diagrams or  failure  to  use  only parts  specifically 

approved  with  this appliance  may  result in property 

damage or personal injury.

 

 

All replacement parts should be ordered from your 

retai

ler or 

 www.woodbridgefp.com 

 

 Item  Description 

QTY 

Part Number

This list contains replaceable parts used in your

 BONFIRE

.

  

  2     Orifice 

1                 F200014

  3 

Flare Coupler

 

1

        

         H100089

    4     Orifice Flex Connector           1                 D300098

    

5

 

Reducing Coupler                 

     H100066

    6 

Main Gas Valve 

1          

       R100026    

 

8

 

    

DFC Control Board

 

1        

 

  

    

  

H

100

142

      

   

 9

     

7V 10mA DC adapter

 

1            

     H

1001

40

      

    

1

1

 

  Mount 

Brackk  et                     

 2

           

    

 F

2

00

022-SS

 

   12      Wall Switch                           1                 A100066

   

1

6

     Pilot Shield 

      D4

00

267

  

   

1

7

     Pilot 

Screen

 

      S5

00

036

  

 

21   Small Basalt Stones             1                 G100049   

 

  20      Black Glass                          1                 G100032            

 

  19      1 pc. LOG SET                     1                 M100503            

1

  

 

 1

8

 

Burner Glass 

Media 

 

             1          

    

 

 

G100048   

  1

4

     

 

Burner 

Tray Weldment          1                W100009 

OPTIONAL TOPPING MEDIA: 

    1     Gas Inlet Flex Connector       1                 D300097

    

7

 

Inlet Coupler                         

     H100002

   1

0

     

DFC Wire Harness

 

 

1           

     

 

H200012

      

  1

3

      Burner 

Weldment                  1                W100001 

 

15 

Pilot Assembly                       1                R100028-SS 

 

 22    Lava Rock                            1                  G100049    

from 

Woodbridge Fireplace Inc.

 at 1-

905

-

564

-

3

001

 or on-line at

Summary of Contents for BONFIRE

Page 1: ... injury or property damage Read the instalation ope rating and maintenance instructions thoroughly before installing or servicing this equipment WARNING DANGER CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor Using it in an enclosed space can kill you Never use this appliance in an enclosed space as a camper tent car or home Version française de ce manuel est dis...

Page 2: ...6 Clothing or other flammable high surface temperatures and should stay away to avoid burns or clothing ignition trical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 if applicable The burner must be replaced prior to the appliance being put into operation if it is evident that the burner is damaged Please refer to Illustrated parts List for the replacement burner part number The appl...

Page 3: ...arameter Model BONFIRE Gas Type Natural S I T Control Valve Model 880 001 Ignition Electronic Manifold Pressure 3 5 w c Inlet Gas Pressure MAX 10 5 w c SPECIFICATIONS Inlet Gas Pressure MIN 5 0 w c Orifice Size 19 64 Shipping Weight Lbs 135 3 input Rate Btu h 192 000 ...

Page 4: ...ted are rapidly dispersed by wind and natural convection 1 When selecting a location for your fireplace ensure that the clearances are followed 2 This appliance must be installed in an open air situation with natural ventilation without stagnant areas where gas leakage and products of combustion radiant heat and could become damaged appliance is used shall comply with one of the following PERMANEN...

Page 5: ...BONFIRE INSTALLATION EXAMPLE Clearance to combustibles must be maintained according to Page 4 5 ...

Page 6: ...erson The appliance should be inspected before use and at least annually by a qualified service person More fre quent cleaning may be required as necessary It is imperative that control compartment burner and circulating air passageways of the appliance be kept clean WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specially approved with this ap...

Page 7: ...ns The gas control inlet is 8 NPT A qualified installer or service person must connect appliance to gas supply Follow all local codes WARNING Use only new black iron or steel pipe Internally tinned copper or copper tubing can be used per National Fuel Code section 2 6 3 providing gas meets hydrogen sulfide limits and where permitted by local codes Gas piping system must be sized to provide minimum...

Page 8: ...Use pipe of 1 2 diameter or greater to allow proper gas volume to of pressure will occur WARNING Test all gas piping and connections for leaks after installing or servicing Correct all leaks at once WARNING Never use an open flame to check for a leak Apply a mixture of liquid soap and water on all joints Bubbles forming show a leak Correct all leaks at once From Gas Meter 5 W C to 10 5 W C pressur...

Page 9: ...LIGHTING INSTRUCTIONS 9 ...

Page 10: ...el 10 Turn on all electric power to the appliance counterclockwise reverse side Close access panel 12 Locate ON OFF switch outside the appliance Turn it to ON 13 The pilot should start sparking and then the pilot flame will appear The main burner should ignite within 4 seconds LIGHTING INSTRUCTIONS Continued 10 ...

Page 11: ...gulfing the flame sensor and the other reaching to the main burner Pilot Flame Inspect area around the burner Remove any lint or foreign material with a brush or vacuum Keepthecontrolcompartment cleanbyvacuumingorbrushingat leasttwiceayear Make sure the burner porting pilot air opening and burner air opening are free of obstructions at all times Keep the appliance and its burner clean by vacuuming...

Page 12: ...create low unavoidable levels of noise Burner flame is too low or too high more flame passage flame pattern and or check for proper orifice sizing 1 Relieve any tight bends or kinks in gas supply line 2 Check reset gas regulator pressure 1 Check for proper gas supply pressure 2 Free burner orifice and manifold ports of any burrs paint or other blockage Note Alltroubleshootingitems arelistedin orde...

Page 13: ...leads disconnected 1 Pilot flame needs adjusting 1 Gas leak See Warning statement above 1 Gas leak See Warning statement above WARNING If you smell gas Shut off gas supply Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions Ifyoucannotreachyourgas...

Page 14: ...16 1 8 5 2 3 6 7 9 10 11 12 ILLUSTRATED PARTS LIST 4 11 14 15 16 13 17 18 14 ...

Page 15: ...ILLUSTRATED PARTS LIST 0 199 039 Pilot Assembly 9 12 10 8 6 15 15 ...

Page 16: ...ILLUSTRATED PARTS LIST FOR PART DESCRIPTION SEE NEXT PAGE LAVAROCK OPTIONAL FIREPLACE TOPPING MEDIA 19 20 21 22 16 1 PC CERAMIC LOG SET BLACK GLASS SMALL STONES ...

Page 17: ...ector 1 D300098 5 Reducing Coupler 1 H100066 6 Main Gas Valve 1 R100026 8 DFC Control Board 1 H100142 9 7V 10mA DC adapter 1 H100140 11 Mount Brackk et 2 F200022 SS 12 Wall Switch 1 A100066 16 Pilot Shield 1 D400267 17 Pilot Screen 1 S500036 21 Small Basalt Stones 1 G100049 20 Black Glass 1 G100032 19 1 pc LOG SET 1 M100503 17 18 Burner Glass Media 1 G100048 14 Burner Tray Weldment 1 W100009 OPTIO...

Page 18: ...127 6 ...

Page 19: ...127 6 ...

Page 20: ... by accident neglect misuse abuse alterations negligence of others including the installation thereof by unqualified installers 2 the costs of removal reinstallation or transportation of defective parts on the appliance or 3 incidental or consequential damage All service work must be performed by an authorized service representative This warranty is expressly in lieu of other warranties express or...

Reviews: