120 VAC ELECTRICAL DIAGRAM
120 VAC MODELS
TYPE 4 CONTROLLER
Single RFG
DATE:
DIAG #:
WD070 Rev. 0
11/14/2014
Bellingham, WA +1(360)650-1111 www.woodstone-corp.com
Radiant
SV2
Junction
Box
L
N
G
CB 4A
GND
XFMR
110-120 VAC
50/60Hz
wired by others
White
Brown
Brown
Blue
Yellow
Temperature Controller
Control Panel Type 4
10
9
8
7
6
5
4
3
2
1
Yellow
Red
+
-
Thermo
Couple