VENTING
FIRE SUPPRESSION
Check with your local code officials to see if fire suppression is required in your area� If fire suppression is required,
you must vent the oven using a Type 1 hood constructed and installed in accordance with NFPA 96� The fusible link in
the hood must be rated at 450 °F minimum� Wood Stone offers Listed exhaust hoods for our ovens that are pre-piped
for ANSUL R-102 fire suppression� All installations are subject to the approval of the local authority having jurisdiction�
INSTALLATION VIEWS OF A WOOD STONE HOOD
Allow sufficient opening
between any facade
and the inside edge of
the front of the hood to
allow for filter removal
and hood cleaning� Any
front facade wall should
not be built any higher
than the top of the oven
to allow for access to
the filter�
Flat face hood
Curved face hood