![Wood Stone BARREL TANDOOR Installation And Operation Manual Download Page 8](http://html1.mh-extra.com/html/wood-stone/barrel-tandoor/barrel-tandoor_installation-and-operation-manual_994345008.webp)
PG
8
OF
20
M0054.07 JULY 2019
Gas-Fired Tandoor CE
Installation and Operation Manual
CLEARANCES & RESTRAINTS
INSTALLATION CLEARANCES
The Wood Stone Square and Round Gas-Fired Tandoor must be
installed with at least 25mm (1") side clearance to combustible
construction� The Barrel Tandoor requires 127mm (5") side clearance
to combustibel construction� Install the unit on a non-combustible
floor, or one provided with a non-combustible covering that extends
at least 92mm (36") in all directions� Any combustible construction
above (overhanging) the appliance should be protected in a manner
acceptable to the authority having jurisdiction�
Do not obstruct the flow of combustion and ventilation air.
Position unit to allow access to unit for servicing.
ENCLOSURES
If the appliance is enclosed, provisions should be made so that it can
easily be removed from the enclosure for service and maintenance�
!
WARNING:
Do not pack required air space (clearance) with insulation or other materials.
When non-combustible building materials contact the body of the Tandoor, the clearances to
combustibles are transferred to those non-combustibles.
EQUIPMENT RESTRAINTS
IMPORTANT NOTICE FOR GAS CONNECTION TO MOVABLE APPLIANCES
When this appliance is installed with casters, it must be installed with the casters supplied, a connector complying with local
codes and a quick disconnect device complying with local codes� It must also be installed with restraining means to guard
against transmission of strain to the connector, as specified below�
ATTENTION INSTALLER: EQUIPMENT RESTRAINT MUST BE PROVIDED
Adequate means must be provided to limit the movement of
the appliance without depending on the connector and the
quick disconnect device or its associated piping to limit the
appliance movement� The hole to attached the restraining
device is in the Burner Assembly frame toward the rear of the
unit, near the gas inlet�
REV:
DATE:
PART #:
Bellingham, WA 360/650-1111 www.woodstone-corp.com
WS-GFT-35-RND
General Arrangement
General Arrangement
10/15/2014
bena
0
DIMENSIONS ARE IN INCHES
TOLERANCES: LINEAR ±1/2 [±10mm], ANGULAR ±2°
UNLESS NOTED OTHERWISE
DWN BY:
SHEET:
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF WOOD STONE CORPORATION
ANY REPRODUCTION OR USE IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF WOOD STONE IS PROHIBITED
An ongoing program of product improvement may require us to
change specifications without notice.
C:\Users\bena\Desktop\001-5035_Dressed-0.dft
1 of 1
Rear view
Hole to attach restraining device
Combustible construction overhanging
the appliance should be protected in
a manner acceptable to the authority
having jurisdiction.
Round or Square models:
25mm (1") side clearance to
combustible construction
Barrel models:
127mm (5") side clearance to
combustible construction
Install on a noncombustible floor, or one protected in a manner
acceptable to the authority having jurisdiction, extending 92
mm (36") in all directions.
Shaded area must be left unobstructed for critical combustion
air and easily accessible for removal of the drip/debris pan and
operation of the pilot safety valve. If this area must be covered,
the cover should be easily removable and heavily perforated.