Troubleshooting Guide
Diagnostics
Troubleshooting Guide
60HD-Rdoc072619
6-31
6
Rev. A4.03+
DTC's (Diagnostic Trouble Codes)
Note
ECU(J1939 Node)
SPN(Suspect Parameter Number)
FMI(Failure Mode Identifier)
Decimal Translation Decimal Translation
Decimal
Translation
4
Shorted To Low Source
**
23
Bed
516113
Toe Board Front Up Solenoid
3
Shorted To High Source
4
Shorted To Low Source
**
23
Bed
516114
Toe Board Rear Down Solenoid
3
Shorted To High Source
4
Shorted To Low Source
**
23
Bed
516115
Toe Board Rear Up Solenoid
3
Shorted To High Source
4
Shorted To Low Source
**
23
Bed
516116
Chain Turner CW Solenoid
3
Shorted To High Source
4
Shorted To Low Source
**
23
Bed
516117
Chain Turner CCW Solenoid
3
Shorted To High Source
4
Shorted To Low Source
**
23
Bed
516118
Side Supports/Turner Up
Solenoid
3
Shorted To High Source
4
Shorted To Low Source
** 23
Bed
516119
Side
Supports/Turner
Down
Solenoid
3
Shorted To High Source
4
Shorted To Low Source
**
23
Bed
516120
Clamp Up Solenoid
3
Shorted To High Source
4
Shorted To Low Source
**
23
Bed
516121
Clamp Down Solenoid
3
Shorted To High Source
4
Shorted To Low Source
**
23
Bed
516122
Clamp In Solenoid
3
Shorted To High Source
4
Shorted To Low Source
**
23
Bed
516123
Clamp Out Solenoid
3
Shorted To High Source
4
Shorted To Low Source
**
23
Bed
516124
Loader Up Solenoid
3
Shorted To High Source
4
Shorted To Low Source
**
23
Bed
516125
Loader Down Solenoid
3
Shorted To High Source
4
Shorted To Low Source
**
23
Bed
516126
Log Deck Forward Solenoid
3
Shorted To High Source
4
Shorted To Low Source
**
23
Bed
516127
Log Deck Reverse Solenoid
3
Shorted To High Source
4
Shorted To Low Source
**
24
Op
516096
Left Joystick X-Axis
3
Shorted To High Source
4
Shorted To Low Source
12 Disconnected
**
24
Op
516097
Left Joystick Y-Axis
3
Shorted To High Source