Setup & Operation
Control Setup
Setup & Operation
60AS-R02doc032519
1-6
1
Adjust Gradient.
If the Accuset is factory-installed, the Gradient Setting is already
set to match the gradient of the transducer sensor (labeled "GRD" on the sensor). If
the Accuset has been installed in the field, the transducer replaced or the Accuset
control has been reset to Factory Settings, the Gradient Setting should be adjusted.
See Figure 1-7.
To enter Configuration Menu 1, push the Up button while in Manual
Mode. Push the button labeled “Calibrate Head”, then the “Adjust Gradient” button to dis-
play the menu below.
See Figure 1-8.
Push the Up or Down buttons until the Gradient Setting is the same as
the sensor gradient shown on the sensor label (use the number labeled “us/in”). Push the
Save Now button to store the new Gradient Setting. If you don’t want to save the new set-
ting and want to return to the previously stored Gradient Setting, push Exit Config and
turn the key switch to the off (#0) position.
FIG. 1-7
FIG. 1-8
Save
Now
Exit
Config
Set Gradient
3H0821-8
9.1292
Use + - buttons to
adjust, then save.
Press UP or DOWN buttons
to adjust Gradient
3H0817-7B
LHSD600U03601R0
S/N: 00245408
GRD: 9.1292us/in | 2782.28m/s
CPN: