Accuset Troubleshooting
Up/Down Control Lights
Accuset Troubleshooting
60AS-R02doc032519
2-10
2
3
If the TL, TR, BR and BL lights do not change properly when pushing the up/down
drum switch,
reset the Accuset to Factory Settings (
See Section 2.2.2 Resetting the
). If the problem has not been eliminated, call Customer Service for assistance.
4
If the UP and DOWN lights do not change properly when pushing the up/down
drum switch,
check the MTRL and MTRR motor wire connections for correct location.
Replace and tighten the wire connections as needed.
DC sawmill only
: If no problems
are found with the wire connections, perform the MOSFET panel test (
MOSFET Panel Test (DC Sawmill Only)
). If the MOSFET panel is okay, reset the Accuset
to Factory Settings (
See Section 2.2.2 Resetting the Accuset
). If the UP and DOWN lights
are still not functioning properly, call Customer Service for assistance.
5
DC sawmill only
:
If the UP and DOWN lights flicker when pushing the up/down
drum switch,
check the MOSFET panel (
See Section 2.3.1 MOSFET Panel Test (DC
). Tighten the wire connections if necessary. If the MOSFET panel has been
replaced before, check the MTRL and MTRR motor wire connections for correct location.
If no problems are found with the wire connections, call Customer Service for assistance.
6
If all the up/down lights are off,
check the power light at the rear of the Accuset front
panel and the power control panel located inside the power box. If the power light is off
See Section 2.2 Accuset Display Problems
for instructions.
DC sawmill only
: If the
power light is on, disconnect and check the MOSFET panel.
to perform the MOSFET test. Replace the MOSFET panel
as needed. If the MOSFET panel has been eliminated as a cause for the problem, per-
form the Accuset reset (
See Section 2.2.2 Resetting the Accuset
). If the problem remains,
call Customer Service for assistance.
2.3.1 MOSFET Panel Test (DC Sawmill Only)
WARNING!
Before performing any service to the sawmill
control box panel, turn the key to the OFF position, discon-
nect the negative battery lead, and remove all rings,
watches, etc.... Failure to do so may cause serious injury
and machine damage.
To perform the MOSFET panel test:
1.
Turn the key switch to the off (#0) position and remove the key.
2.
Remove the eight screws securing the MOSFET panel.