Troubleshooting Guide
Power Feed Problems
4
4-6
3087doc041610
Troubleshooting Guide
Power feed is binding
Adjust belt tension; Check condition of
belt, pulleys, bearings, and sprocket;
Check motor for ground fault. Allow
motor to cool before restarting
Saw head load is excessive
Avoid unnecessary modifications to
saw heads that would give them extra
weight. Allow motor to cool before
restarting
Blade is dull or improperly set
Use proper blade maintenance proce-
dures.
See Sharpener or Toothsetter
manual.
Allow motor to cool before
restarting