Mini Boiler Owners Manual
2015
Safety
• Never shut power off to the burner without allowing the burner to complete its shut down process unless
there is an emergency.
• Take the proper precautions to ensure that the modifications made to an existing heating system does not
interfere with existing safety controls.
• Never use the following: trash, plastics, gasoline, rubber, or naphtha in your WoodMaster Boiler.
• Read and follow these directions carefully. Retain this manual for as long as you own your boiler.
Sweeping
The chimney should be inspected and cleaned as needed, typically twice a year. This is to be done by qualified
persons. Shut off the boiler and Renovator, disconnect power and allow the system to cool before attempting
to clean the system.
Warning!
Always disconnect the power to the boiler/burner before any cleaning or maintenance. Service agreements
increases operation length and life of the unit. For more information contact your local WoodMaster dealer.
Replacement parts should only be genuine Northwest Manufacturing, Inc. components. Your dealer can supply
the genuine service parts and install them. They can then reevaluate the system and provide a flue gas analy
-
sis. Failure to perform a flue gas analysis may void your warranty.
Emission Standards
Visit the EPA Burnwise website, http://www.epa.gov/burnwise/index.html for information on wood fuel fired
appliances, as well as a list of approved appliances.
Safety Standards
Guardian info: Solid Fuel Burner System. Listed by Guardian Fire Testing Laboratories Inc. Tested and listed
to The Applicable Sections of UL-391, ETLM 78-1, ASTM-E 1509, UL2523 & CAN/CSA-B366.1 EPA EXEMPT PER
40CFR60.53A, METHOD 28A
AMSE H Stamp certified pressure boiler.
SOLID FUEL BURNER SYSTEM
Listed By: GUARDIAN FIRE TESTING LABORATORIES, INC.
Tested and Listed to the Applicable Sections of UL-391, ETLM 78-1, ASTM-E-1509, &
CAN/CSA-B366.1, EPA EXEMPT PER 40CFR60.53A, METHOD 28A
Make/Model:
WoodMaster/MB 30kw
Production Date Code:
Manufacturer:
Northwest Mfg., Inc. WoodMaster
Test Date:
Electrical
Rating:
10/13/2014
6A, 120V, 60HZ
Fuel:
WOOD PELLETS, 10% MAXIMUM MOISTURE
CONTENT. LESS THAN 1% ASH CONTENT
Serial No.:
MB30-XXXX
GUARDIAN
Certified by
Northwest
Manufacturing
Inc.
MAWP. Water _________
Maximum Water Temp. _________
Heating Surface _________boiler
Heating Surface _________water wall
Heating Surface _________extended
Ext HS generating cap _______
Minimum relief valve capacity _______
Mfg. Serial No. ____________
Year built_______
30 psi
250
4432
250
20XX
MB30-XXXX