Page 15 / 28
Control Panel Operation
1.
Plug in the electrical cord to a properly grounded 15A, 110VAC outlet (surge protector recommended).
2.
Turn the rear switch on. The controller will display the welcome screen, then the default display.
3.
Press and hold “set” to enter the programming menu to set the time & date.
4.
Press “Control Mode” to cycle to the mode desired:
a.
“
Manual
” (constant heat output, adjustable level 1-5)
b.
“
Temperature
” (maintain an adjustable temperature set point, idles @ level 1 and heats @ level 5)
c.
“
Weekly
” (4 programmable set points for each day of the week, idles @ level 1 and heats @ level 5)
5.
Pressing “On/Off” will start the “Ignite” phase. The exhaust blower will turn on which causes the vacuum switch to
close and the igniter also turns on. Pellets will fall into the burn pot shortly and ignite in 3-5 minutes.
6.
Once the units gets up to temperature and the exhaust blower temperature sensor closes, the stove will switch to
“Heating” mode. The igniter will turn off and the room blower will turn on to heat the home.
Bottom Status Icon Legend (in order of left-to-right):
Igniter On:
Exhaust Blower Running:
Auger Motor Running:
Room Blower Running:
Vacuum Switch Closed:
Hopper Lid Closed:
Advanced Controller Operation
Manual Mode
Adjust heat output level from 1-5 stalls (bars) by pressing the up and down arrows while on or off.
Temperature Mode
Adjust the temperature set point from 45 to 90 degrees by pressing the up and down arrows while on or off. Setting
above 80 may result in tripping the high temperature sensor if air circulation in the room is not sufficient and may require
a small fan blowing towards the back or side of the unit to keep it cool.
Weekly Mode
There are 4 different time sections for each day of the week with each section able to automatically turn the stove on,
change the temperature set point or turn the stove off. There is a minimum of 30 minutes allowed between any time
section. For a set point change while running, the stove will shut down and re-start automatically 30 minutes later at the
new programmed set point.