7. TECHNICAL DATA
Technical Data
ECOMPACT 40
Page 32
© Wood Energy Solutions
woodenergysolutions.co.uk
Boiler Model
E-Compact L40
E
n
e
rg
y
Nominal (Max) Rated Output - kW
40
Reduced Rated Output (30%) - Kw
12
Boiler Class
5
Efficiency at Nominal Output - %
94
Test Standard
EN303-5:1999
W
a
te
r
Water Capacity - litres
76
Waterside Resistance - mbar
35
Operating Temperature Range - °C
60-85
Recommended Return Temperature
60
Maximum Operating Pressure - bar
2
Fl
u
e
G
a
s
Flue Gas Temperature at Maximum Rated Output
175
Flue Gas Temperature at Reduced Rated Output
110
Flue Oulet Diameter - mm
146
Recommended Flue Diameter - mm
150
Flue Draft Required at Reduced / Nominal Output - Pa
10/25
Fu
e
l
Fuel
6mm Wood Pellets
Fuel Standard
EnPlus - A1
C
o
n
n
e
ct
io
n
s
Water Flow Connection - inch
1 1/4" (DN 65)
Water Return Connection - inch
1 1/4" (DN 65)
Water Drain Connection - inch
1" (DN 25)
Safety Valve / Air Vent Connection - inch
1/2" (DN 15)
E
le
ct
ri
ca
l
Electrical Supply
230V 50Hz 0.6A
Current at Start-Up - Amp
2.5A
Auxilliary Power at Reduced / Nominal - Watts
132 - 417 W
Standby Power - Watts
6.7W
Total Dry Weight - kg
375kg